Key result
Longer door-to-device time is linked to lower LVEF and extended CCU stays in STEMI.
Why the study?
Does prolonged door-to-device (DTD) time predict worse short-term clinical and echocardiographic outcomes in STEMI patients undergoing primary percutaneous coronary intervention?
Cross-Sectional (n=163)
Yes
Does prolonged door-to-device (DTD) time predict worse short-term clinical and echocardiographic outcomes in STEMI patients undergoing primary percutaneous coronary intervention?
Answers are grounded in this paper and cite their sources.
Prolonged door-to-device time during primary percutaneous coronary intervention for STEMI significantly predicts reduced LVEF and prolonged CCU stays, emphasizing the necessity of adhering to guidelines for rapid reperfusion.
BACKGROUND: Primary percutaneous coronary intervention (PPCI) is considered the gold standard for ST-elevation myocardial infarction (STEMI) treatment. While door-to-device (DTD) time critically influences outcomes, its combined impact with baseline characteristics requires further investigation. METHODS: In this descriptive cross-sectional analytical study, 163 patients with STEMI undergoing PPCI were recruited through convenience sampling at two hospitals affiliated with Ahvaz Jundishapur University of Medical Sciences between November 2024 and May 2025. Data were collected via hospital records and a researcher-designed checklist covering demographic and clinical variables. Statistical analyses were performed using SPSS version 26. RESULTS: The mean age of participants was 57.55 ± 13.19 years, and 85.9% were male. The mean DTD time was 108.08 minutes. Longer DTD time was significantly associated with prolonged CCU stay (r = 0.335, p < 0.001) and lower left ventricular ejection fraction (LVEF) (r = -0.232, p = 0.003). Although DTD time did not differ significantly between survivors and non-survivors (p = 0.573), it varied significantly across different degrees of myocardial injury (p = 0.027). Multivariate regression analysis showed that male gender (β = -8.007, p = 0.002), increased DTD time (β = -0.043, p = 0.005), and myocardial injury (β = -14.904, p = 0.016) were significantly associated with reduced LVEF. Increased DTD time (β = 0.014, p < 0.001) and decreased LVEF (β = -0.061, p = 0.003) were significantly associated with longer CCU stays. CONCLUSION: While baseline characteristics showed minimal impact, DTD time significantly predicted worse outcomes, including prolonged CCU stays, reduced LVEF, and myocardial injury. These findings emphasize the critical importance of reducing DTD time (<60 minutes) through optimized emergency protocols to improve STEMI management outcomes.
No takes yet. Share an insight, caveat, or question.
Vosoughi et al. (2026) conducted a cross-sectional in ST-elevation myocardial infarction (STEMI) (n=163). Door-to-device (DTD) time vs. Shorter DTD time was evaluated on Left ventricular ejection fraction (LVEF) (β = -0.043, 95% CI -0.073 to -0.013, p=0.005). Increased door-to-device time was associated with reduced left ventricular ejection fraction and longer coronary care unit stays in STEMI patients undergoing PPCI.
Synapse has enriched 10 related papers. Consider them for comparative context: