Why the study?
Multiple trials show renal denervation reduces blood pressure compared with sham control, but the comparative antihypertensive efficacy of radiofrequency versus ultrasound-based renal denervation remained uncertain.
Does ultrasound renal denervation improve blood pressure reduction compared to radiofrequency renal denervation in patients with hypertension?
Does ultrasound renal denervation improve blood pressure reduction compared to radiofrequency renal denervation in patients with hypertension?
Both radiofrequency and ultrasound renal denervation significantly reduce blood pressure compared to sham, but ultrasound may offer greater reductions in ambulatory blood pressure at 4 months.
Answers are grounded in this paper and cite their sources.
Ultrasound renal denervation may be preferred over radiofrequency for greater ambulatory SBP reduction; extends direct RCT comparative evidence.
BACKGROUND AND AIMS: Multiple randomized trials have shown that renal denervation (RDN) reduces blood pressure (BP) when compared with sham control but the antihypertensive efficacy of radiofrequency vs. ultrasound-based RDN is uncertain. We aimed to compare the outcomes of radiofrequency RDN (rRDN) and ultrasound RDN (uRDN), when compared with sham in patients with hypertension. METHODS: PubMed, EMBASE, and clinicaltrials.gov databases were searched for randomized sham-controlled trials (RCTs) of rRDN or uRDN or for trials of rRDN vs. uRDN. Primary efficacy outcome was 24-h ambulatory SBP. A mixed treatment comparison meta-analysis was performed comparing the efficacy and safety against sham and against each other. RESULTS: Among 13 RCTs that enrolled 2285 hypertensive patients, rRDN reduced 24-h ambulatory SBP [(MD = 2.34 mmHg; 95% confidence interval (95% CI): 0.72-3.95], office SBP (MD = 5.04 mmHg; 95% CI: 2.68-7.40)], and office DBP (MD = 2.95 mmHg; 95% CI: 1.68-4.22) when compared with sham. Similarly, uRDN reduced 24-h ambulatory SBP (MD = 4.74 mmHg; 95% CI: 2.80-6.67), day-time ambulatory SBP (MD = 5.40 mmHg; 95% CI: 3.68-7.13), night-time ambulatory SBP (MD = 3.84 mmHg; 95% CI: 0.02-7.67), and office SBP (3.98 mmHg; 95% CI: 0.78-7.19) when compared with sham. There was significantly greater reduction in 24-h ambulatory SBP (MD = 2.40 mmHg; 95% CI: 0.09-4.71), day-time ambulatory SBP (MD = 4.09 mmHg; 95% CI: 1.61-6.56), and night-time ambulatory SBP (MD = 5.76 mmHg; 95% CI: 0.48-11.0) with uRDN when compared with rRDN. For primary efficacy outcome, uRDN ranked #1, followed by rRDN (#2), and sham (#3). CONCLUSION: In hypertensive patients, rRDN and uRDN significantly reduced 24-h ambulatory and office SBP when compared with sham control with significantly greater reduction in ambulatory BP with uRDN than with rRDN at 4 months (mean) of follow-up. A large-scale randomized head-to-head trial of rRDN or uRDN is warranted to evaluate if there are differences in efficacy.
No takes yet. Share an insight, caveat, or question.
Bangalore et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: