Why the study?
LBBAP was reported to improve cardiac function by correcting CLBBB, but its efficacy compared with BIVP in heart failure patients with CLBBB needed evaluation.
Does left bundle branch area pacing improve CRT response and cardiac function compared to biventricular pacing in heart failure patients with complete left bundle branch block?
Does left bundle branch area pacing improve CRT response and cardiac function compared to biventricular pacing in heart failure patients with complete left bundle branch block?
Left bundle branch area pacing provides superior electrical synchrony and higher CRT response rates compared to traditional biventricular pacing in heart failure patients with complete left bundle branch block.
BACKGROUND: Left bundle branch area pacing (LBBAP) was reported to improve cardiac function by correcting complete left bundle branch block (CLBBB). Our study aimed to compare the efficacy of LBBAP and biventricular pacing (BIVP) in heart failure patients with CLBBB. METHODS: Ten patients prospectively underwent LBBAP (LBB-CRT group) and 30 patients received BIVP (BIV-CRT group) were matched using propensity score matching. LBBAP was achieved by the trans-interventricular septum method. Echocardiography, electrocardiogram, NYHA classification, and blood B-type natriuretic peptide concentration were evaluated at preimplantation and at 6-month follow up. CRT response was defined as at least 15% decrease in left ventricular end-systolic volume. RESULTS: In the LBB-CRT group, CLBBB were successfully corrected by LBBAP with no complications. QRS duration (QRSd) significantly decreased after implantation in both groups, and the decrease of QRSd in the LBB-CRT group was significantly greater than that in the BIV-CRT group (60.80 ± 20.09 vs. 33.00 ± 21.48 ms, p = .0009). The echocardiographic measurements including left ventricular end-diastolic diameter, left ventricular end-systolic diameter, and left ventricular ejection fraction significantly improved after 6 months in both groups. The response rate was significantly higher in LBB-CRT group than BIV-CRT group (100.00% vs. 63.33%, p = .038). The percentage of patients in New York Heart Association classification Grades I and II was significantly higher in the LBB-CRT group compared with that in the BIV-CRT group (median 1.5 vs. 2.0, p = .029) at 6-month follow-up. CONCLUSIONS: It is effective and safe to correct CLBBB with LBBAP in heart failure patients. Compared with BIVP, LBBAP can better optimize electrical synchrony and improve cardiac function.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: