Key result
Beat-to-beat BP variability is linked to ~3 g/m2 higher LV mass index independent of BP level.
Why the study?
Is blood pressure variability associated with target organ damage independent of blood pressure level in untreated subjects?
Observational (n=256)
Is blood pressure variability associated with target organ damage independent of blood pressure level in untreated subjects?
Short-term beat-to-beat blood pressure variability is more strongly associated with target organ damage than day-to-day home blood pressure variability, independent of absolute blood pressure levels.
Answers are grounded in this paper and cite their sources.
Beat-to-beat BP variability may identify higher target organ damage risk independent of mean BP; hypothesis-generating and should not yet change practice.
Whether target organ damage is associated with blood pressure (BP) variability independent of level remains debated. We assessed these associations from 10-minute beat-to-beat, 24-hour ambulatory, and 7-day home BP recordings in 256 untreated subjects referred to a hypertension clinic. BP variability indices were variability independent of the mean, maximum-minimum difference, and average real variability. Effect sizes (standardized β) were computed using multivariable regression models. In beat-to-beat recordings, left ventricular mass index (n=128) was not (P≥0.18) associated with systolic BP but increased with all 3 systolic variability indices (+2.97-3.53 g/m(2); P<0.04); the urinary albumin-to-creatinine ratio increased (P≤0.03) with systolic BP (+1.14-1.17 mg/mmol) and maximum-minimum difference (+1.18 mg/mmol); and pulse wave velocity increased with systolic BP (+0.69 m/s; P<0.001). In 24-hour recordings, all 3 indices of organ damage increased (P<0.03) with systolic BP, whereas the associations with BP variability were nonsignificant (P≥0.15) except for increases in pulse wave velocity (P<0.05) with variability independent of the mean (+0.16 m/s) and maximum-minimum difference (+0.17 m/s). In home recordings, the urinary albumin-to-creatinine ratio (+1.27-1.30 mg/mmol) and pulse wave velocity (+0.36-0.40 m/s) increased (P<0.05) with systolic BP, whereas all associations of target organ damage with the variability indices were nonsignificant (P≥0.07). In conclusion, while accounting for BP level, associations of target organ damage with BP variability were readily detectable in beat-to-beat recordings, least noticeable in home recordings, with 24-hour ambulatory monitoring being informative only for pulse wave velocity.
No takes yet. Share an insight, caveat, or question.
Wei et al. (2014) conducted an observational in Hypertension (n=256). Blood pressure variability (beat-to-beat, 24-hour ambulatory, 7-day home) vs. Blood pressure level was evaluated on Target organ damage (left ventricular mass index, urinary albumin-to-creatinine ratio, pulse wave velocity). Blood pressure variability was associated with target organ damage independent of BP level in beat-to-beat recordings, but less so in home recordings.
Synapse has enriched 10 related papers. Consider them for comparative context: