Key result
National holidays are linked to a transient ~1.1 Ohm drop in thoracic impedance and reduced HRV.
Why the study?
Higher myocardial infarction incidence during national holidays could relate to dietary overindulgence straining vulnerable hearts, prompting investigation into cardiac metrics and fluid accumulation via CIED monitoring during these periods.
Does exposure to national holidays alter thoracic impedance, heart rate variability, and physical activity in patients with cardiac implantable electronic devices?
Observational (n=96)
No
Does exposure to national holidays alter thoracic impedance, heart rate variability, and physical activity in patients with cardiac implantable electronic devices?
National holidays are associated with transient fluid accumulation (decreased thoracic impedance), reduced heart rate variability, and decreased physical activity in patients with CIEDs.
Answers are grounded in this paper and cite their sources.
May signal transient fluid shifts during holidays in CIED patients; hypothesis-generating for targeted monitoring strategies.
AIMS: The higher incidence of myocardial infarction (MI) during national holidays could be caused by overindulgence of food and beverages, potentially straining the heart of vulnerable individuals. Monitoring decreased thoracic impedance by cardiac implantable electronic devices (CIED) can be used for detection of fluid accumulation. We aimed to assess the relationship between cardiac metrics and national holidays in patients with CIED. METHODS AND RESULTS: Patients with CIED-based impedance monitoring at a tertiary care hospital in Sweden were screened. Patients were included if they had data for at least one holiday (Christmas, New Year, or Midsummer) between June 2015 and January 2020. Thoracic impedance, heart rate variability, and activity during the holiday were compared with baseline values, defined as the average of 3 days preceding Christmas and Midsummer. Clinical characteristics were obtained from medical records. In total, 96 patients (82% men, age 69 ± 10 years, 92% ICD, 78% CRT, 72% with LVEF < 40%) were included, which provided data for 649 patient-holidays. During Christmas Day, New Year's Day, and Midsummer Day combined, impedance decreased by a mean of 1.1 Ohm [95% CI 0.7-1.6, P < 0.001], heart rate variability decreased by a mean of 8.0 ms [4.9-11.2, P > 0.001] and daily activity by a mean of 40 min [35-45, P < 0.001]. One ventricular tachycardia event requiring shock therapy was documented during the holiday. CONCLUSION: A transient decrease in thoracic impedance, heart rate variability, and physical activity was observed during national holidays, potentially contributing to the higher incidence of MI during holidays.
No takes yet. Share an insight, caveat, or question.
Olsson et al. (2025) conducted an observational in Patients with cardiac implantable electronic devices (CIED) (n=96). National holidays (Christmas, New Year, Midsummer) vs. Baseline values (average of 3 days preceding the holidays) was evaluated on Thoracic impedance (Mean decrease 1.1 Ohm, 95% CI 0.7-1.6, p=<0.001). National holidays were associated with a transient decrease in thoracic impedance by a mean of 1.1 Ohm, reduced heart rate variability, and decreased physical activity.