Key result
Sequential head-up tilt testing in patients with recent syncope showed decreasing reproducibility of a positive response, dropping from 80% at 1 week to 53% at 2 weeks.
Why the study?
What is the reproducibility of sequential head-up tilt testing in patients with recent syncope, normal ECG, and no structural heart disease?
RCT (n=127)
Randomized
What is the reproducibility of sequential head-up tilt testing in patients with recent syncope, normal ECG, and no structural heart disease?
The reproducibility of a positive head-up tilt test decreases over time and shows significant intra-individual variation, whereas a negative response has high reproducibility.
Answers are grounded in this paper and cite their sources.
Positive tilt test reproducibility declines after 1 week in recent syncope; challenges reliance on serial testing for consistent diagnosis.
AIMS: To assess the reproducibility of the response to sequential head-up tilt tests. METHODS AND RESULTS: A head-up tilt test was performed early after syncope in 127 patients with a normal ECG and no structural heart disease. Patients with a positive response (82 patients) were randomized to two (1 week and 2 weeks later) or one (2 weeks later) additional head-up tilt tests, and patients with a negative response (45 patients) were randomized to a second head-up tilt test 1 or 2 weeks after the first. The reproducibility of a positive response in the second head-up tilt test was 80% after 1 week and 53% after 2 weeks (P<0.01). Only 53% of the patients with a positive response to a first and second head-up tilt test had a positive response to a third (P=0.01). Intra-individual variation in the time to a positive response was wide. The reproducibility of the cardioinhibitory responses was very poor. Reproducibility of a negative response was 80%. CONCLUSIONS: In patients with recent syncope, the rate of positive responses decreases with sequential head-up tilt tests. Furthermore, the time to a positive response in different head-up tilt tests shows important intra-individual variations, and the reproducibility of the cardioinhibitory responses is very poor. In contrast, the reproducibility of the negative responses is high.
No takes yet. Share an insight, caveat, or question.
Jaume Sagristà-Sauleda (2002) conducted an RCT in Recent syncope (n=127). Sequential head-up tilt testing at 1 week vs. Sequential head-up tilt testing at 2 weeks was evaluated on Reproducibility of a positive response in the second head-up tilt test (p=<0.01). Sequential head-up tilt testing in patients with recent syncope showed decreasing reproducibility of a positive response, dropping from 80% at 1 week to 53% at 2 weeks.
Synapse has enriched 10 related papers. Consider them for comparative context: