Key result
Real-time 3D echo parameter Tmsv16-SD% predicts ~334% greater odds of CRT response.
Why the study?
To assess the predictive efficacy of real-time 3D echocardiography and QRS wave duration in determining CRT response and assessing left ventricular systolic function.
Does real-time three-dimensional echocardiography (RT-3DE) improve the prediction of response to cardiac resynchronization therapy compared to QRS wave duration in patients with heart failure?
Cohort (n=51)
No
Does real-time three-dimensional echocardiography (RT-3DE) improve the prediction of response to cardiac resynchronization therapy compared to QRS wave duration in patients with heart failure?
Answers are grounded in this paper and cite their sources.
Real-time 3D echocardiography, specifically the Tmsv16-SD parameter, offers superior predictive accuracy for CRT response compared to traditional QRS duration.
BACKGROUND: The aim of this study is to assess the predictive efficacy of real-time three-dimensional echocardiography (RT-3DE) and QRS wave duration in determining the response to cardiac resynchronization therapy (CRT) and assessing left ventricular systolic function pre- and post-CRT device implantation. METHOD: A total of 51 patients with heart failure undergoing CRT at the Second Affiliated Hospital of Nantong University between January 1, 2013, and October 31, 2020, were enrolled in this study. Traditional two-dimensional echocardiography and RT-3DE were performed pre and post-CRT, with QRS wave width data from electrocardiograms and additional clinical information collected. Patients were categorized into CRT responder (n = 36) and CRT non-responder (n = 15) groups based on their response to CRT device implantation. Comparative analyses were conducted on the general characteristics of both groups, as well as the predictive efficacy of RT-3DE and QRS wave width for CRT responsiveness and left ventricular systolic function. Data on the standard deviation (Tmsv16-SD, Tmsv12-SD, Tmsv6-SD) and maximum difference (Tmsv16-Dif, Tmsv12-Dif, Tmsv6-Dif) of left ventricular end-systolic volume (LVESV) at segments 16, 12, and 6, as well as QRS wave width, were collected and analyzed. RESULTS: The indicators Tmsv6-Dif, Tmsv12-Dif, Tmsv16-Dif, Tmsv6-SD, Tmsv12-SD, Tmsv16-SD, and QRS wave width exhibited significantly higher values in the CRT responder group when compared to the CRT non-responder group (P < 0.05). Among these, Tmsv16-SD demonstrated superior predictive performance for post-CRT response, with a sensitivity of 88.9%, specificity of 80.0%, and a diagnostic cut-off value of 6.19%. This predictive capability exceeded that of the conventional indicator, QRS wave width. CONCLUSION: RT-3DE enables accurate prediction of post-CRT patient response and significantly facilitates quantitative assessment of CRT therapy efficacy.
No takes yet. Share an insight, caveat, or question.
Zhou et al. (2024) conducted a cohort in Heart failure undergoing cardiac resynchronization therapy (n=51). Real-time three-dimensional echocardiography (RT-3DE) parameter Tmsv16-SD% vs. QRS wave width was evaluated on Postoperative responsiveness to CRT (OR 4.337, 95% CI 1.414-13.299, p=0.010). Real-time 3D echocardiography parameter Tmsv16-SD% independently predicted postoperative responsiveness to cardiac resynchronization therapy with 88.9% sensitivity and 80.0% specificity.
Synapse has enriched 10 related papers. Consider them for comparative context: