Key result
A 4DCT-derived lead placement score identifies CRT responders with an 87% AUC.
Why the study?
Although CRT is effective for heart failure, 30% of patients do not respond, motivating patient-specific left ventricle maps of lead placement scores to identify target pacing sites for higher response probability.
Does a lead placement score derived from 4-dimensional computed tomography predict cardiac resynchronization therapy response in patients with heart failure?
Observational (n=82)
Does a lead placement score derived from 4-dimensional computed tomography predict cardiac resynchronization therapy response in patients with heart failure?
A lead placement score derived from 4-dimensional computed tomography accurately predicts CRT response, highlighting its potential utility in guiding patient selection and lead placement.
Answers are grounded in this paper and cite their sources.
4D-CT lead placement scoring may predict CRT responders; hypothesis-generating and requires prospective validation before clinical use.
BACKGROUND: Cardiac resynchronization therapy (CRT) is an effective treatment for patients with heart failure; however, 30% of patients do not respond to the treatment. We sought to derive patient-specific left ventricle maps of lead placement scores (LPS) that highlight target pacing lead sites for achieving a higher probability of CRT response. METHODS: Eighty-two subjects recruited for the ImagingCRT trial (Empiric Versus Imaging Guided Left Ventricular Lead Placement in Cardiac Resynchronization Therapy) were retrospectively analyzed. All 82 subjects had 2 contrast-enhanced full cardiac cycle 4-dimensional computed tomography scans: a baseline and a 6-month follow-up scan. CRT response was defined as a reduction in computed tomography-derived end-systolic volume ≥15%. Eight left ventricle features derived from the baseline scans were used to train a support vector machine via a bagging approach. An LPS map over the left ventricle was created for each subject as a linear combination of the support vector machine feature weights and the subject's own feature vector. Performance for distinguishing responders was performed on the original 82 subjects. An LPS threshold that maximized the geometric mean of true-negative and true-positive rates identified 26/30 of the nonresponders. The area under the curve of the receiver operating characteristic curve for identifying responders with an LPS threshold was 87%. CONCLUSIONS: An LPS map was defined using 4-dimensional computed tomography-derived features of left ventricular mechanics. The LPS correlated with CRT response, reclassifying 25% of the subjects into low probability of response, 25% into high probability of response, and 50% unchanged. These encouraging results highlight the potential utility of 4-dimensional computed tomography in guiding patient selection for CRT. The present findings need verification in larger independent data sets and prospective trials.
No takes yet. Share an insight, caveat, or question.
Manohar et al. (2022) conducted an observational in Heart failure (n=82). Lead placement score (LPS) derived from 4-dimensional computed tomography was evaluated on CRT response (reduction in computed tomography-derived end-systolic volume ≥15%) (AUC 87%). A lead placement score derived from 4-dimensional computed tomography identified cardiac resynchronization therapy responders with an AUC of 87%.
Synapse has enriched 10 related papers. Consider them for comparative context: