Key result
Computational pipeline predicts postoperative mitral valve geometry within 1 mm after undersized ring annuloplasty.
Why the study?
Long-term outcomes of mitral valve repair remain suboptimal and difficult to predict, and preoperative optimization is complicated by MR heterogeneity and multiple repair configurations.
A novel patient-specific computational pipeline using standard-of-care pre-operative imaging can accurately predict postoperative mitral valve geometry and strain following undersized ring annuloplasty.
Answers are grounded in this paper and cite their sources.
Computational mitral modeling shows promise for annuloplasty planning; leaves open effects on outcomes and requires prospective validation.
While mitral valve (MV) repair remains the preferred clinical option for mitral regurgitation (MR) treatment, long-term outcomes remain suboptimal and difficult to predict. Furthermore, pre-operative optimization is complicated by the heterogeneity of MR presentations and the multiplicity of potential repair configurations. In the present work, we established a patient-specific MV computational pipeline based strictly on standard-of-care pre-operative imaging data to quantitatively predict the post-repair MV functional state. First, we established human mitral valve chordae tendinae (MVCT) geometric characteristics obtained from five CT-imaged excised human hearts. From these data, we developed a finite-element model of the full patient-specific MV apparatus that included MVCT papillary muscle origins obtained from both the in vitro study and the pre-operative three-dimensional echocardiography images. To functionally tune the patient-specific MV mechanical behavior, we simulated pre-operative MV closure and iteratively updated the leaflet and MVCT prestrains to minimize the mismatch between the simulated and target end-systolic geometries. Using the resultant fully calibrated MV model, we simulated undersized ring annuloplasty (URA) by defining the annular geometry directly from the ring geometry. In three human cases, the postoperative geometries were predicted to 1 mm of the target, and the MV leaflet strain fields demonstrated close agreement with noninvasive strain estimation technique targets. Interestingly, our model predicted increased posterior leaflet tethering after URA in two recurrent patients, which is the likely driver of long-term MV repair failure. In summary, the present pipeline was able to predict postoperative outcomes from pre-operative clinical data alone. This approach can thus lay the foundation for optimal tailored surgical planning for more durable repair, as well as development of mitral valve digital twins.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2023) studied Mitral regurgitation (n=8). Patient-specific mitral valve computational pipeline was evaluated on Postoperative mitral valve geometry prediction accuracy. A patient-specific computational pipeline predicted postoperative mitral valve geometries to within 1 mm of the target in three human cases undergoing undersized ring annuloplasty.
Synapse has enriched 10 related papers. Consider them for comparative context: