Why the study?
Does treatment with Ender pins reduce secondary operations and loss of fixation compared with a compression hip-screw in patients with unstable intertrochanteric fractures of the hip?
Does treatment with Ender pins reduce secondary operations and loss of fixation compared with a compression hip-screw in patients with unstable intertrochanteric fractures of the hip?
Ender pins are associated with a higher rate of secondary operations and loss of fixation compared to compression hip-screws for unstable intertrochanteric hip fractures.
Answers are grounded in this paper and cite their sources.
Compression hip-screw preferred over Ender pins to minimize reoperations; supports abandoning Ender pins for unstable intertrochanteric fractures.
In a prospective, consecutive, randomized study of the treatment of unstable intertrochanteric fractures of the hip, the use of Ender pins was compared with the use of the compression hip-screw. There were more than 100 patients in each treatment group. The patients who were alive six months postoperatively were evaluated. The number of secondary operations was much higher in the patients who were treated with Ender pins, and a considerably higher number of those patients had loss of fixation. The use of Ender pins that were too long and a history of a fracture before the operation in which Ender pins were used were statistically significant predictors of secondary operations.
No takes yet. Share an insight, caveat, or question.
Sernbo et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: