Key result
Reducing LVAD pump speed to restore pulsatile flow cuts MSNA by ~20%.
Why the study?
Does the restoration of pulsatile flow through pump speed modulation reduce muscle sympathetic nerve activity in patients with continuous-flow left ventricular assist devices?
Does the restoration of pulsatile flow through pump speed modulation reduce muscle sympathetic nerve activity in patients with continuous-flow left ventricular assist devices?
Absolute Event Rate: 33% vs 41%
p-value: p=<0.01
Restoration of pulsatile flow by reducing LVAD pump speed decreases muscle sympathetic nerve activity, likely via the arterial baroreceptor reflex.
Hypothesis-generating for sympathetic modulation via LVAD speed adjustment; prospective outcome trials needed before practice consideration.
BACKGROUND: Current-generation left ventricular assist devices provide circulatory support that is minimally or entirely nonpulsatile and are associated with marked increases in muscle sympathetic nerve activity (MSNA), likely through a baroreceptor-mediated pathway. We sought to determine whether the restoration of pulsatile flow through modulations in pump speed would reduce MSNA through the arterial baroreceptor reflex. METHODS AND RESULTS: Ten men and 3 women (54 ± 14 years) with Heartmate II continuous-flow left ventricular assist devices underwent hemodynamic and sympathetic neural assessment. Beat-to-beat blood pressure, carotid ultrasonography at the level of the arterial baroreceptors, and MSNA via microneurography were continuously recorded to determine steady-state responses to step changes (200-400 revolutions per minute) in continuous-flow left ventricular assist device pump speed from a maximum of 10,480 ± 315 revolutions per minute to a minimum of 8500 ± 380 revolutions per minute. Reductions in pump speed led to increases in pulse pressure (high versus low speed: 17 ± 7 versus 26 ± 12 mm Hg; P<0.01), distension of the carotid artery, and carotid arterial wall tension (P<0.05 for all measures). In addition, MSNA was reduced (high versus low speed: 41 ± 15 versus 33 ± 16 bursts per minute; P<0.01) despite a reduction in mean arterial pressure and was inversely related to pulse pressure (P=0.037). CONCLUSIONS: Among subjects with continuous-flow left ventricular assist devices, the restoration of pulsatile flow through modulations in pump speed leads to increased distortion of the arterial baroreceptors with a subsequent decline in MSNA. Additional study is needed to determine whether reduction of MSNA in this setting leads to improved outcomes.
No takes yet. Share an insight, caveat, or question.
Cornwell et al. (2015) studied Continuous-flow left ventricular assist devices (n=13). Reduction in pump speed vs. High pump speed was evaluated on Muscle sympathetic nerve activity (MSNA) in bursts per minute (p=<0.01). Restoring pulsatile flow by reducing continuous-flow LVAD pump speed decreased muscle sympathetic nerve activity from 41 to 33 bursts per minute (P<0.01).