Key result
Bicuspid aortic valve donor hearts show 100% pediatric transplant survival without intervention at six years.
Why the study?
Does the use of donor hearts with bicuspid aortic valves result in acceptable graft longevity and valvular function in pediatric heart transplant recipients?
Case Report (n=4)
No
Does the use of donor hearts with bicuspid aortic valves result in acceptable graft longevity and valvular function in pediatric heart transplant recipients?
Pediatric heart transplantation using donor hearts with functionally normal bicuspid aortic valves shows acceptable intermediate-term graft longevity and valvular function, suggesting it should not be an absolute contraindication.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for bicuspid aortic valve donors in pediatric heart transplant; larger prospective studies needed to confirm durability.
BACKGROUND: Valvular disease in pediatric and young adult donor hearts may be a relative contraindication to graft use. Outcomes following the use of donor hearts with bicuspid aortic valve (BAV) have not been previously reported in children. We describe 4 cases of pediatric heart transplantation (HTx) utilizing a donor heart with a BAV. CASE SERIES: Of the 469 HTx included in this study, 4 utilized a donor heart with a BAV. All recipients were female; median age was 11 years (range 0.3 to 19 years). In all cases, the BAV was not discovered until after HTx. All donors were less than 30 years old. The patients were followed for a median of 6 years (range 2 to 9 years) with all patients alive at last follow-up. Two patients have transitioned to adult care, and 2 patients continue to follow in our clinic. In follow-up, no patient has required an aortic valve intervention or had infective endocarditis. At last review, no patient had greater than mild aortic insufficiency or more than mild aortic stenosis. Three patients developed mild-to-moderate left ventricular hypertrophy in the first year post-transplant that improved over time. One patient experienced a peri-operative embolic stroke at time of transplant unrelated to the BAV. CONCLUSION: On short- and intermediate-term follow-up, pediatric and young adult donor hearts with BAV demonstrated acceptable graft longevity and valvular function. A functionally normal BAV in a pediatric heart transplant donor should not be a contraindication to organ acceptance.
No takes yet. Share an insight, caveat, or question.
Day et al. (2021) conducted a case report in Pediatric heart transplantation (n=4). Donor heart with bicuspid aortic valve was evaluated on Survival and need for aortic valve intervention. Pediatric heart transplantation utilizing donor hearts with bicuspid aortic valves resulted in 100% survival and no requirement for aortic valve intervention at a median follow-up of 6 years.
Synapse has enriched 10 related papers. Consider them for comparative context: