Key result
Intraoperative external pressure to expand the aortic annulus allows proper-sized valve insertion in 55% of patients.
Why the study?
Does intraoperative application of external pressure to increase the transverse axis of the aortic annulus facilitate the insertion of a proper sized prosthetic valve in patients undergoing aortic valve replacement?
Observational (n=22)
No
Does intraoperative application of external pressure to increase the transverse axis of the aortic annulus facilitate the insertion of a proper sized prosthetic valve in patients undergoing aortic valve replacement?
Answers are grounded in this paper and cite their sources.
Intraoperative application of external pressure to the aortic annulus allowed for the successful insertion of a larger, appropriately sized prosthetic valve in 55% of patients without procedural complications, potentially aiding in overcoming prosthesis-patient mismatch.
Background: Surgical method was introduced for enhancement of prosthetic valve insertion and overcoming difficulties ensourcing from prosthesis-patient mismatch. Methods: Twenty-two patients that underwent aortic valve replacement between January 2005 and July 2009 were included in this prospective study. In these patients, the insertion of prosthesis larger than the annulus diameter was attempted after the application of an external pressure that increased the transverse axis diameter of the aortic annulus. The postoperative results and complications were assessed. Results: This surgical method was performed on 22 patients (16 males, 6 females, mean age: 52.2 ± 15.8 years) during the valve replacement. In 12 patients (55%), replacement of proper sized aortic valve compliant to their surface area was accomplished, while the insertion of a proper valve could not be achieved in 10 (45%) of the patients. No perioperative mortality or complications related to the procedure were reported. Conclusion: Increasing the transverse diameter of aortic valve may not only facilitate the insertion of a prosthetic valve but also aid in overcoming prosthesis-patient mismatch. Further studies on larger series are necessary to document the actual effectively and precise selection criteria for application of this method.
No takes yet. Share an insight, caveat, or question.
Bozok et al. (2015) conducted an observational in Aortic valve disease requiring replacement (n=22). Intraoperative application of external pressure to increase the transverse axis of the aortic annulus was evaluated on Replacement of proper-sized aortic valve compliant to body surface area. Intraoperative application of external pressure to increase the transverse axis of the aortic annulus allowed the insertion of a proper-sized aortic valve compliant to body surface area in 55% of patients.