Key result
AV-synchronous DDD pacing increases stroke volume ~17% versus VVI pacing, though prior AMI attenuates benefit.
Why the study?
The extent of hemodynamic benefit from AV-synchronous pacing in patients with sinus rhythm and AV block is not completely understood.
Does AV-synchronous pacing (DDD) improve stroke volume compared to AV-asynchronous pacing (VVI) in patients in sinus rhythm with previous dual chamber pacemaker implantation?
RCT (n=40)
Randomized crossover sequence
No
Does AV-synchronous pacing (DDD) improve stroke volume compared to AV-asynchronous pacing (VVI) in patients in sinus rhythm with previous dual chamber pacemaker implantation?
AV-synchronous DDD pacing significantly increases stroke volume compared to VVI pacing in patients with sinus rhythm and AV block, though the benefit is attenuated in those with prior myocardial infarction.
Answers are grounded in this paper and cite their sources.
Supports DDD over VVI pacing for acute hemodynamic gain in sinus rhythm; extends AV synchrony evidence, attenuated post-AMI.
Introduction The extent of the hemodynamic benefit from AV-synchronous pacing in patients with sinus rhythm and AV block is not completely understood. Thus, we systematically investigated the association of an array of echocardiographic and epidemiological parameters with the change in cardiac output depending on the stimulation mode (AV-synchronous or AV-asynchronous pacing). Methods Patients in sinus rhythm after previous dual chamber pacemaker implantation underwent a thorough basic echocardiographic assessment of diastolic and systolic left ventricular function, and atrial function (26 echo parameters, including novel speckle tracking strain measurements). Then, stroke volume was measured with AV-synchronous (DDD) and AV-asynchronous (VVI) pacing. Each patient represented their own control, and the sequence of stroke volume measurements was randomized. Results In this prospective single-center study (NCT04068233, registration August 22nd 2019), we recruited 40 individuals. The stroke volume was higher in all patients when applying AV-synchronous DDD pacing [median increase 12.8 ml (16.9%), P < 0.001]. No echo parameter under investigation was associated with the extent of stroke volume increase in a linear regression model. Of all epidemiological variables, a history of acute myocardial infarction (AMI) was associated with an attenuated stroke volume gain in a univariate and a multivariate regression model that adjusted for confounders. A- and S-wave velocities were reduced in the AMI group. Discussion In our cohort of patients, each subject benefited from AV-synchronous DDD pacing. No single echo parameter could predict the amount of stroke volume increase. The beneficial effect of AV-synchronous pacing on stroke volume was attenuated after prior acute myocardial infarction. ClinicalTrials.gov identifier (NCT number): NCT04068233.
No takes yet. Share an insight, caveat, or question.
Blessberger et al. (2023) conducted an RCT in Sinus rhythm and AV block with previous dual chamber pacemaker (n=40). AV-synchronous pacing (DDD) vs. AV-asynchronous pacing (VVI) was evaluated on Stroke volume (Median increase 12.8 ml (16.9%), p=<0.001). AV-synchronous DDD pacing significantly increased stroke volume compared to AV-asynchronous VVI pacing (median increase 12.8 ml, 16.9%; P<0.001), though this benefit was attenuated after prior AMI.