Key result
MultiPoint Pacing marginally improves acute hemodynamics by ~1% over biventricular pacing, requiring patient-specific AV delays.
Why the study?
CRT benefits in heart failure depend on device programming, particularly AVD and LV pacing site selection, prompting comparison of hemodynamic AVD optimization across BiV and MPP LV vector selection strategies.
Does MultiPoint Pacing improve acute hemodynamics compared to conventional biventricular pacing in patients receiving CRT-D?
Does MultiPoint Pacing improve acute hemodynamics compared to conventional biventricular pacing in patients receiving CRT-D?
Absolute Event Rate: 25.8% vs 24.5%
p-value: p=0.040
MultiPoint Pacing provides greater acute hemodynamic improvement than conventional biventricular pacing, but patient-specific atrioventricular delay programming is critical for optimal response.
Should not yet alter CRT-D programming; leaves open whether MPP yields clinically meaningful benefit in randomized trials.
Background The benefits of cardiac resynchronization therapy (CRT) in heart failure patients have been shown to depend on device programming, particularly atrioventricular delay (AVD) and left ventricular (LV) pacing site selection. This study compared the hemodynamic AVD optimization for commonly used biventricular (BiV) and MultiPoint Pacing(MPP, Abbott) LV vector selection strategies. Methods After de novo CRT‐D (Abbott Quadra Assura MP) and quadripolar LV lead (Abbott Quartet) implant, acute LV pressure was measured across a range of AVDs (60–225 ms) in four pacing modes: BiV with most proximal cathode, BiV with most distal cathode, MPP using two cathodes with earliest and latest right ventricle (RV)–LV activation times, and MPP using two cathodes with maximal anatomical separation. Hemodynamic improvement was evaluated by changes in maximum LV pressure first‐derivative versus RV pacing (Δ dP / dt ). Results Twenty patients (64 years old, 68% male) completed the acute pacing protocol at six centers in China. Hemodynamic improvement versus RV pacing for BiV (proximal), BiV (Distal), MPP (electrical), and MPP (anatomical) was 22.1% ± 13.6%, 23.7% ± 13.4%, 24.5% ± 13.4%, and 25.1% ± 13.9%, respectively. The best MPP setting was marginally superior to the best BiV across all patients (25.8% ± 13.4% vs. 24.5% ± 13.1%, p = .040) and in the majority of patients (75.0% vs. 25.0%, p = .004). AVD programmed as little as 20 ms from optimum significantly reduced the Δ dP / dt benefit for all modes. Conclusions The maximal hemodynamic improvement across AV delays in this population was greater with MPP than BiV. Furthermore, patient‐specific AVD programming was critical in achieving the full hemodynamic response for all BiV and MPP modes.
No takes yet. Share an insight, caveat, or question.
Hua et al. (2022) studied Heart failure (n=20). MultiPoint Pacing (MPP) vs. Biventricular (BiV) pacing was evaluated on Hemodynamic improvement (changes in maximum LV pressure first-derivative versus RV pacing) (p=0.040). MultiPoint Pacing was marginally superior to biventricular pacing for acute hemodynamic improvement (25.8% vs 24.5%, p=0.040), and patient-specific atrioventricular delay programming was critical.