Why the study?
Does optimizing AV delay based on intrinsic conduction intervals improve acute haemodynamic response in heart failure patients undergoing CRT with quadripolar leads?
Does optimizing AV delay based on intrinsic conduction intervals improve acute haemodynamic response in heart failure patients undergoing CRT with quadripolar leads?
In patients receiving CRT with quadripolar leads, the optimal AV delay is similar across various pacing configurations including multi-point pacing, and can be effectively approximated at 50% of the RAp-RVs interval.
Patient-specific AV optimization via intrinsic intervals may enhance acute response in quadripolar CRT; leaves open long-term clinical benefit.
AIMS: This study aims to define an atrioventricular (AV) delay optimization method for cardiac resynchronization therapy (CRT) with a quadripolar left ventricular (LV) lead based on intrinsic conduction intervals. METHODS AND RESULTS: Heart failure patients with a left bundle branch block underwent CRT implantation with a quadripolar LV lead. Invasive LV pressure-volume loops were recorded during four biventricular and three multi-point pacing (MPP) settings, using four patient-specific paced AV delays. Haemodynamic response was defined as change in stroke work (Δ%SW) compared to intrinsic rhythm and was related to the following conduction intervals: right atrial pacing to right ventricular sensing interval (RAp-RVs), Q to LV sensing interval normalized to QRS duration (QLV/QRSd), PR-interval, and P-wave duration. In 44 patients, the largest Δ%SW (104 ± 76%) occurred at a paced AV delay of 128 ± 32 ms, at 47 ± 9% of RAp-RVs. Optimal AV delay of biventricular pacing (126 ± 26 ms) did not differ from MPP (126 ± 21 ms, P = 0.29). Intra-class correlation coefficient between optimal AV delays of different pacing configurations was 0.64 (0.45-0.78, P < 0.001). Although not statistically significant, Δ%SW at 50% of RAp-RVs (98 ± 74%) was closer to the maximal achievable Δ%SW increase than a fixed interval of 120 ms (96 ± 73%, P = 0.60). RAp-RVs, QLV/QRSd, PR interval, and P-wave duration were associated with the optimal AV delay in univariate analysis, but only RAp-RVs remained significantly associated in multivariate analysis (R = 0.69). CONCLUSION: The AV delay that provides highest haemodynamic response is similar for various LV pacing configurations and for MPP. An AV delay ∼50% of RAp-RVs creates an acute haemodynamic response close to the maximal patient-specific response.
No takes yet. Share an insight, caveat, or question.
Everdingen et al. (2018) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: