Why the study?
In aortic stenosis, mean arterial pressure does not reflect true left ventricular afterload, prompting evaluation of whether a gradient-adjusted cardiac power index improves post-TAVR survival prediction over cardiac power alone.
Does a gradient-adjusted cardiac power index improve prediction of 1-year survival in patients undergoing TAVR compared to standard cardiac power index?
Does a gradient-adjusted cardiac power index improve prediction of 1-year survival in patients undergoing TAVR compared to standard cardiac power index?
Gradient-adjusted cardiac power index does not offer incremental prognostic value over standard cardiac power index for predicting 1-year survival after TAVR.
Answers are grounded in this paper and cite their sources.
Gradient-adjusted indices add no value for post-TAVR survival prediction; hypothesis-generating and should not yet change practice.
PURPOSE: Cardiac power (CP) index is a product of mean arterial pressure (MAP) and cardiac output (CO). In aortic stenosis, however, MAP is not reflective of true left ventricular (LV) afterload. We evaluated the utility of a gradient-adjusted CP (GCP) index in predicting survival after transcatheter aortic valve replacement (TAVR), compared to CP alone. MATERIALS AND METHODS: We included 975 patients who underwent TAVR with 1 year of follow-up. CP was calculated as (CO×MAP)/[451×body surface area (BSA)] (W/m²). GCP was calculated using augmented MAP by adding aortic valve mean gradient (AVMG) to systolic blood pressure (CP1), adding aortic valve maximal instantaneous gradient to systolic blood pressure (CP2), and adding AVMG to MAP (CP3). A multivariate Cox regression analysis was performed adjusting for baseline covariates. Receiver operator curves (ROC) for CP and GCP were calculated to predict survival after TAVR. Both CP and GCP were independently associated with survival at 1 year. The area under ROCs for CP, CP1, CP2, and CP3 were 0.67 [95% confidence interval (CI), 0.62-0.72], 0.65 (95% CI, 0.60-0.70), 0.66 (95% CI, 0.61-0.71), and 0.63 (95% CI 0.58-0.68), respectively. CONCLUSION: GCP did not improve the accuracy of predicting survival post TAVR at 1 year, compared to CP alone.
No takes yet. Share an insight, caveat, or question.
Agasthi et al. (2020) studied this question.