Key result
Novel biodegradable envelope and suture orientation stabilize S-ICD generators and promote tissue regeneration.
Why the study?
Failure to attain stabilization of the subcutaneous implantable cardioverter-defibrillator generator to the chest wall can cause elevated shock impedance, altered defibrillation threshold, and changes in the QRST sensing vector.
Does a novel biodegradable bio envelope and suture orientation effectively stabilize the subcutaneous implantable cardioverter-defibrillator generator to the chest wall?
Does a novel biodegradable bio envelope and suture orientation effectively stabilize the subcutaneous implantable cardioverter-defibrillator generator to the chest wall?
Answers are grounded in this paper and cite their sources.
A novel bio envelope and suture orientation may provide effective stabilization of SICD generators to prevent elevated shock impedance and sensing vector changes.
Key Teaching Points•The defibrillation threshold in the subcutaneous implantable cardioverter-defibrillator (SICD) is influenced by variables related to patient anatomy, plane, orientation of the generator, and coil position.•Failure to attain stabilization of the SICD generator to the chest wall can result in an elevated shock impedance, a change in defibrillation threshold, and change in QRST sensing vector.•A novel biodegradable bio envelope and suture orientation can be used to effectively stabilize the SICD generator to the chest wall and promote tissue regeneration. •The defibrillation threshold in the subcutaneous implantable cardioverter-defibrillator (SICD) is influenced by variables related to patient anatomy, plane, orientation of the generator, and coil position.•Failure to attain stabilization of the SICD generator to the chest wall can result in an elevated shock impedance, a change in defibrillation threshold, and change in QRST sensing vector.•A novel biodegradable bio envelope and suture orientation can be used to effectively stabilize the SICD generator to the chest wall and promote tissue regeneration.
No takes yet. Share an insight, caveat, or question.
Xiang et al. (2019) studied Subcutaneous implantable cardioverter-defibrillator (SICD) implantation. Novel biodegradable bio envelope and suture orientation was evaluated on Stabilization of the SICD generator to the chest wall. A novel biodegradable bio envelope and suture orientation can effectively stabilize the subcutaneous implantable cardioverter-defibrillator generator to the chest wall and promote tissue regeneration.