Why the study?
Does CRT using quadripolar left ventricular leads reduce mortality and heart failure hospitalization compared to non-quadripolar leads in patients receiving CRT?
Does CRT using quadripolar left ventricular leads reduce mortality and heart failure hospitalization compared to non-quadripolar leads in patients receiving CRT?
The use of quadripolar left ventricular leads in CRT is associated with significantly lower total mortality, cardiac mortality, and heart failure hospitalizations compared to non-quadripolar leads.
Answers are grounded in this paper and cite their sources.
Quadripolar leads were associated with lower mortality in CRT; hypothesis-generating and requires RCT confirmation before practice change.
Background In cardiac resynchronization therapy ( CRT ), quadripolar ( QUAD ) left ventricular ( LV ) leads are less prone to postoperative complications than non‐ QUAD leads. Some studies have suggested better clinical outcomes. Methods and Results Clinical events were assessed in 847 patients after CRT ‐pacing or CRT‐defibrillation using either QUAD (n=287) or non‐ QUAD (n=560), programmed to single‐site site LV pacing. Over a follow‐up period of 3.2 years (median [interquartile range, 1.90–5.0]), QUAD was associated with a lower total mortality (adjusted hazard ratio [ aHR ]: 0.32, 95% confidence interval [ CI ], 0.20–0.52), cardiac mortality ( aHR : 0.36, 95% CI , 0.20–0.65), and heart failure ( HF ) hospitalization ( aHR : 0.62, 95% CI , 0.39–0.99), after adjustment for age, sex, New York Heart Association class, HF etiology, device type ( CRT ‐pacing or CRT ‐defibrillation), comorbidities, atrial rhythm, medication, left ventricular ejection fraction, and creatinine. Death from pump failure was lower with QUAD ( aHR : 0.33; 95% CI , 0.18–0.62), but no group differences emerged with respect to sudden cardiac death. There were no differences in implant‐related complications. Re‐interventions for LV displacement or phrenic nerve stimulation, which were lower with QUAD , predicted total mortality ( aHR : 1.68, 95% CI , 1.11–2.54), cardiac mortality ( aHR : 2.61, 95% CI , 1.66–4.11) and HF hospitalization ( aHR : 2.09, 95% CI, 1.22–3.58). Conclusions CRT using QUAD , programmed to biventricular pacing with single‐site LV pacing, is associated with a lower total mortality, cardiac mortality, and HF hospitalization. These trends were observed for both CRT ‐defibrillation and CRT ‐pacing, after adjustment for HF cause and other confounders. Re‐intervention for LV lead displacement or phrenic nerve stimulation was associated with worse outcomes.
No takes yet. Share an insight, caveat, or question.
Leyva et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: