Key result
Complete pocket resection with regional flap closure shows 0% reinfection and mortality in CIED infections.
Why the study?
Recommendations vary regarding wound management after hardware extraction for cardiac implantable electronic device infections, with conservative, time-consuming approaches like open packing and negative-pressure therapy generally recommended alongside long intervals before reimplantation.
Does complete pocket resection with regional flap closure prevent reinfection and mortality in patients with cardiac implantable electronic device infections?
Observational (n=42)
No
Does complete pocket resection with regional flap closure prevent reinfection and mortality in patients with cardiac implantable electronic device infections?
An aggressive approach of complete hardware removal, excisional debridement, and regional flap closure for CIED infections allowed for early reimplantation with zero mortality or reinfections in a 42-patient series.
Supports aggressive management of CIED infections; hypothesis-generating and requires prospective validation before practice change.
Background: Cardiac implantable electronic device infections are associated with substantial morbidity and mortality. There are varied recommendations in the literature about treatment of the wound after extraction of all hardware, but only conservative, time-consuming approaches such as open packing and negative-pressure therapy along with a long interval before reimplanting any hardware have generally been recommended for the treatment. 1–4 Methods: A retrospective review was performed of 42 patients treated at Jersey Shore University Medical Center for implantable cardioverter defibrillator and permanent pacemaker infections between July 2010 and April 2018 with an aggressive, multidisciplinary approach utilizing an invasive cardiologist and a plastic surgeon. Clinical and demographic data were collected, and a descriptive analysis was conducted. Results: A total of 42 patients, with a median age of 76 years, were selected for our treatment of pacemaker pocket infection. Patients underwent removal of all hardware followed by debridement and flap closure of the wound soon after extraction. Reimplantation was performed when indicated typically within a week after initial extraction and typically on the contralateral side. There were no reports of reinfection and no mortality in all 42 patients treated. Conclusion: We found that the aggressive removal of all hardware and excisional debridement of the entire capsule followed by flap coverage and closure of the wound allowed for a shortened interval to reimplantation with no ipsilateral or contralateral infections during the follow-up period.
No takes yet. Share an insight, caveat, or question.
Hansalia et al. (2019) conducted an observational in Cardiac implantable electronic device (CIED) infections (n=42). Complete pocket resection with regional flap closure was evaluated on Reinfection and mortality. Complete pocket resection with regional flap closure resulted in no reinfections and no mortality among 42 patients treated for cardiac implantable device infections.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: