Why the study?
Electrical storm is a clinical emergency characterized by multiple malignant ventricular arrhythmias or ICD discharges within 24 hours that requires early rational management.
Is bedside zero-fluoroscopy temporary permanent pacemaker implantation with the EnSite system feasible and safe for treating electrical storm?
Is bedside zero-fluoroscopy temporary permanent pacemaker implantation with the EnSite system feasible and safe for treating electrical storm?
Bedside zero-fluoroscopy temporary permanent pacemaker implantation using the EnSite 3D system may be a feasible and safe emergency treatment for electrical storm.
Answers are grounded in this paper and cite their sources.
May support emergency zero-fluoroscopy pacing in electrical storm; hypothesis-generating case report requiring prospective validation.
Background Electrical storm (ES) is a clinical emergency characterized by multiple malignant ventricular arrhythmias or ICD discharges within 24 h, requiring early rational management. Case presentation We report a 55-year-old man who underwent aortic valve replacement experienced recurrent ventricular tachycardia/ventricular fibrillation. A temporary permanent pacemaker with the EnSite system was implanted, and significant inhibition of the electrical storm, attributed to the atrial overdrive pacing, ensued. Conclusions In emergency regarding an electrical storm, the bedside temporary permanent pacemaker implantation with the EnSite system is concluded to be feasible and safe.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: