Key result
CMR-derived RVEDVi and LA GLS predict volumetric response to CRT.
Why the study?
The role of CMR-derived strain parameters in predicting volumetric response to CRT was unexplored.
Do CMR-derived right ventricular and left atrial strain parameters predict volumetric response to cardiac resynchronization therapy?
Cohort (n=50)
Do CMR-derived right ventricular and left atrial strain parameters predict volumetric response to cardiac resynchronization therapy?
CMR-derived right ventricular and left atrial strain parameters, along with RV volumes, can help predict echocardiographic volumetric response to cardiac resynchronization therapy.
Background: While left-bundle-branch-block-related contraction patterns as well as echocardiography-derived strain are variably associated with the volumetric response to cardiac resynchronization therapy (CRT), the role of CMR-derived strain parameters is unexplored. Methods: A total of 50 patients receiving CRT implantation were retrospectively analyzed, all of whom had undergone CMR imaging within one year before, and echocardiography within 6 months before and 6–12 months after CRT implantation. We assessed CMR-derived morphological and functional parameters with regard to the echocardiographic response, defined as a reduction in the left ventricular end-systolic volume of ≥15%. Results: Among the standard CMR parameters, the indexed right ventricular volumes in end-diastole (RVEDVi) (74.5 ± 19.5 vs. 94.8 ± 30.2 mL/m2, p = 0.006) and end-systole (RVESVi) (43.2 ± 13.3 vs. 61.6 ± 28.8 mL/m2, p = 0.003), as well as the left atrial (LA) area (24.8 ± 3.5 vs. 30.4 ± 9.5 cm2, p = 0.020), differed significantly between CRT responders and non-responders. In strain analysis, CRT responders showed a significantly better LA global longitudinal strain (GLS) (25.1 ± 10.4 vs. 15.3 ± 10.5, p = 0.002), LA global circumferential strain (GCS) (27.9 ± 14.7 vs. 17.1 ± 13.1%, p = 0.012), RV GLS (−25.0 ± 6.5 vs. −18.9 ± 7.6%, p = 0.004) and RV free wall strain (−31.1 ± 7.9 vs. −24.9 ± 9.5, p = 0.017). Conclusions: CMR-derived peak septal circumferential strain and RVEDVi correlated with the echocardiographic volumetric response to CRT at 6–12 months.
No takes yet. Share an insight, caveat, or question.
Ching et al. (2025) conducted a cohort in Patients receiving cardiac resynchronization therapy (n=50). CMR-derived strain parameters was evaluated on Echocardiographic response (reduction in left ventricular end-systolic volume of ≥15%). CMR-derived right ventricular end-diastolic volume index (74.5 vs 94.8 mL/m2, p=0.006) and left atrial global longitudinal strain (25.1 vs 15.3, p=0.002) predicted volumetric response to CRT.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: