Key result
Four-dimensional analysis of dynamic CT images demonstrated a mean downward movement of the aortic root of 9.13 ± 1.86 mm and a rotation of 11.8 ± 4.60°.
Why the study?
Aortic root motion is suspected to contribute to proximal aortic dissection, but quantitative displacement and rotation remain unknown.
Cross-Sectional (n=40)
In vivo spatial and temporal displacement of the aortic root can be successfully quantified using multiphase ECG-gated contrast-enhanced CT images, providing baseline metrics for normal 4D motion.
Provides normative 4D aortic root motion metrics on CT; leaves open utility for valve interventions pending prospective validation.
Aims Aortic root motion is suspected to contribute to proximal aortic dissection. While motion of the aorta in four dimensions can be traced with real-time imaging, displacement and rotation in quantitative terms remain unknown. The hypothesis was to show feasibility of quantification of three-dimensional aortic root motion from dynamic CT imaging. Methods and results Dynamic CT images of 40 patients for coronary assessment were acquired using a dynamic protocol. Scans were ECG-triggered and segmented in 10 time-stepped phases (0–90%) per cardiac cycle. With identification of the sinotubular junction (STJ), a patient-specific co-ordinate system was created with the z-axis (out-of-plane) parallel to longitudinal direction. The left and right coronary ostia were traced at each time-step to quantify downward motion in reference to the STJ plane, motion within the STJ plane (in-plane), and the degree of rotation. Enrolled individuals had an age of 65 ± 12, and 14 were male (35%). The out-of-plane motion was recorded with the largest displacement of 10.26 ± 2.20 and 8.67 ± 1.69 mm referenced by left and right coronary ostia, respectively. The mean downward movement of aortic root was 9.13 ± 1.86 mm. The largest in-plane motion was recorded at 9.17 ± 2.33 mm and 6.51 ± 1.75 mm referenced by left and right coronary ostia, respectively. The largest STJ in-plane motion was 7.37 ± 1.96 mm, and rotation of the aortic root was 11.8 ± 4.60°. Conclusion In vivo spatial and temporal displacement of the aortic root can be identified and quantified from multiphase ECG-gated contrast-enhanced CT images. Knowledge of normal 4D motion of the aortic root may help understand its biomechanical impact in patients with aortopathy and pre- and post-surgical or transcatheter aortic valve replacement.
No takes yet. Share an insight, caveat, or question.
Yuan et al. (2024) conducted a cross-sectional in Patients undergoing coronary assessment (n=40). Dynamic CT imaging was evaluated on Quantification of three-dimensional aortic root motion. Four-dimensional analysis of dynamic CT images demonstrated a mean downward movement of the aortic root of 9.13 ± 1.86 mm and a rotation of 11.8 ± 4.60°.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: