Key result
Isometric handgrip contraction induced a gradual ~25 mmHg increase in mean arterial pressure, reflecting an upward shift in the arterial baroreflex set point without altering baroreflex sensitivity.
Why the study?
Does isometric handgrip induce a progressive increase in arterial pressure and a linear increase in the setpoint for arterial pressure control?
Does isometric handgrip induce a progressive increase in arterial pressure and a linear increase in the setpoint for arterial pressure control?
Isometric handgrip induces a progressive increase in mean arterial pressure by gradually increasing the set point of arterial baroreflexes without altering their responsiveness.
Answers are grounded in this paper and cite their sources.
Isometric handgrip may drive progressive pressor responses via baroreflex resetting; extends mechanistic insight but leaves open clinical relevance.
AIM: The hypothesis that isometric handgrip induces a progressive increase in arterial pressure and a linear increase in setpoint for arterial pressure control was tested. METHODS: The continuous time course of changes in heart rate (HR), stroke volume (SV) and mean arterial pressure (MAP) was recorded during a 2-min handgrip contraction of 40% of maximal voluntary contraction force. Twice during the development of the handgrip-induced, gradual pressure increase of ∼25 mmHg, additional, transient changes in arterial pressure were mechanically induced. The subsequent baroreflex responses to these additional pressure changes were studied. The additional steep increase in arterial pressure (∼10 mmHg) was induced both after 70 and 100 s of handgrip contraction, by inflating bilateral thigh cuffs to suprasystolic pressure. Cuff pressure was released after 10s, thus introducing a steep decrease in MAP. RESULTS: During the development of the handgrip-induced pressure increase, HR increased, SV decreased, cardiac output (CO) increased slightly and total peripheral conductance (TPC=CO/MAP) increased (i.e. peripheral vasoconstriction). The circulatory responses to the additional, sudden increase and subsequent decrease in arterial pressure after 70 and 100 s perfectly adjusted arterial pressure back to the linear increase in MAP, indicating an effective baroreflex response. CONCLUSION: The increase in MAP which characterizes handgrip-induced pressure response can be regarded as a result of a gradual increase in the set point of the arterial baroreflexes, with no change in the time course and magnitude of the baroreflex responses to additional, induced changes in MAP.
No takes yet. Share an insight, caveat, or question.
Karin Toska (2010) studied this question. Isometric handgrip contraction was evaluated on Changes in heart rate, stroke volume, mean arterial pressure, and baroreflex responses. Isometric handgrip contraction induced a gradual ~25 mmHg increase in mean arterial pressure, reflecting an upward shift in the arterial baroreflex set point without altering baroreflex sensitivity.
Synapse has enriched 10 related papers. Consider them for comparative context: