Key result
Low-intensity cardiopulmonary exercise testing (CPX) for A-V interval optimization was feasible in 94.1% of patients, compared to 88.2% using resting echocardiography.
Why the study?
Is low-intensity cardiopulmonary exercise testing (CPX) feasible for determining the optimal A-V interval in patients undergoing CRT optimization compared to resting methods?
Observational (n=17)
Is low-intensity cardiopulmonary exercise testing (CPX) feasible for determining the optimal A-V interval in patients undergoing CRT optimization compared to resting methods?
Exercise-based A-V interval optimization using low-intensity cardiopulmonary exercise testing is highly feasible and safe in patients undergoing cardiac resynchronization therapy.
Answers are grounded in this paper and cite their sources.
Supports exploring low-intensity CPX for A-V optimization in CRT; leaves open impact on outcomes versus resting echo.
BACKGROUND: One-third of eligible patients fail to respond to cardiac resynchronization therapy (CRT). Current methods to "optimize" the atrio-ventricular (A-V) interval are performed at rest, which may limit its efficacy during daily activities. We hypothesized that low-intensity cardiopulmonary exercise testing (CPX) could identify the most favorable physiologic combination of specific gas exchange parameters reflecting pulmonary blood flow or cardiac output, stroke volume, and left atrial pressure to guide determination of the optimal A-V interval. METHODS: We assessed relative feasibility of determining the optimal A-V interval by three methods in 17 patients who underwent optimization of CRT: (1) resting echocardiographic optimization (the Ritter method), (2) resting electrical optimization (intrinsic A-V interval and QRS duration), and (3) during low-intensity, steady-state CPX. Five sequential, incremental A-V intervals were programmed in each method. Assessment of cardiopulmonary stability and potential influence on the CPX-based method were assessed. RESULTS: CPX and determination of a physiological optimal A-V interval was successfully completed in 94.1% of patients, slightly higher than the resting echo-based approach (88.2%). There was a wide variation in the optimal A-V delay determined by each method. There was no observed cardiopulmonary instability or impact of the implant procedure that affected determination of the CPX-based optimized A-V interval. CONCLUSIONS: Determining optimized A-V intervals by CPX is feasible. Proposed mechanisms explaining this finding and long-term impact require further study.
No takes yet. Share an insight, caveat, or question.
Choudhuri et al. (2014) conducted an observational in Heart failure requiring cardiac resynchronization therapy (CRT) (n=17). Low-intensity cardiopulmonary exercise testing (CPX) for A-V interval optimization vs. Resting echocardiographic optimization (Ritter method) and resting electrical optimization was evaluated on Feasibility of determining the optimal A-V interval. Low-intensity cardiopulmonary exercise testing (CPX) for A-V interval optimization was feasible in 94.1% of patients, compared to 88.2% using resting echocardiography.
Synapse has enriched 10 related papers. Consider them for comparative context: