Key result
Leadless LV endocardial pacing improves functional class and increases LVEF by ~6% from baseline.
Why the study?
The study was conducted to appraise and compare cardiac resynchronization therapy employing leadless left ventricular endocardial pacing with an ultrasound transmitter.
Does cardiac resynchronization therapy employing leadless left ventricular endocardial pacing with an ultrasound transmitter improve NYHA class and LVEF in subjects with dyssynchronous heart failure?
Meta-Analysis (n=272)
Yes
Does cardiac resynchronization therapy employing leadless left ventricular endocardial pacing with an ultrasound transmitter improve NYHA class and LVEF in subjects with dyssynchronous heart failure?
Leadless left ventricular endocardial pacing with an ultrasound transmitter significantly improves NYHA functional class and LVEF in patients with dyssynchronous heart failure, serving as a potential alternative for those who cannot receive or failed conventional CRT.
Answers are grounded in this paper and cite their sources.
Provides alternative for CRT-ineligible patients; extends evidence for leadless endocardial pacing in dyssynchronous HF.
The purpose of the study was to appraise and compare cardiac resynchronization therapy (CRT) employing leadless left ventricular endocardial pacing (LVEP) with an ultrasound transmitter. The meta-analysis employed continuous random or fixed effect models to get mean difference (MD) with 95% confidence intervals (CIs). 6 papers with a total of 272 subjects, available between 2014 and 2022, were included in this meta-analysis from a search in PubMed, Cochrane Library, Google Scholar, OVID, and Embase databases. Follow-up New York Heart Association had a significantly lower mean reduction in New York Heart Association functional class (MD, -0.44; 95% CI, -0.68 - -0.19, p < 0.001) with high heterogeneity (I2 = 77%) compared to baseline New York Heart Association in subjects with dyssynchronous heart failure. Also, follow-up left ventricular ejection fraction had a significantly higher mean increase in left ventricular ejection fraction (MD, 5.65; 95% CI, 3.99–7.31, p < 0.001) with no heterogeneity (I2 = 3%) compared to baseline left ventricular ejection fraction in subjects with dyssynchronous heart failure. Leadless LVEP works well for CRT, so it can be used as a second-line treatment for people who can’t get normal CRT or it hasn’t worked for them. As the safety profile gets better, more people will be able to get this medicine for these patients. However, given that most of the studies comprised a small sample size of all the selected studies and a pre-post design, attention should be given to their values.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2025) conducted a meta-analysis in Dyssynchronous heart failure (n=272). Leadless left ventricular endocardial pacing (LVEP) with an ultrasound transmitter vs. Baseline was evaluated on Reduction in New York Heart Association functional class (MD -0.44, 95% CI -0.68 - -0.19, p=<0.001). Leadless left ventricular endocardial pacing reduced New York Heart Association functional class and increased left ventricular ejection fraction from baseline.
Synapse has enriched 10 related papers. Consider them for comparative context: