Key result
Edge-detected common carotid artery IMT was associated with incident coronary heart disease, whereas manual-traced IMT was not.
Why the study?
Does automated edge-detected common carotid artery IMT measurement predict incident coronary heart disease better than manual-traced IMT in adults free of baseline CHD?
Cohort (n=5,468)
Yes
Does automated edge-detected common carotid artery IMT measurement predict incident coronary heart disease better than manual-traced IMT in adults free of baseline CHD?
Automated edge-detected measurement of carotid intima-media thickness is a stronger predictor of incident coronary heart disease than manual tracing.
Answers are grounded in this paper and cite their sources.
Automated edge-detected IMT may aid CHD risk stratification; leaves open validation before replacing manual tracing in practice.
BACKGROUND: Common carotid artery intima-media thickness (IMT) can be measured either by hand or with an automated edge detector. We performed a direct comparison of these 2 approaches and studied their respective associations with coronary heart disease outcomes. METHODS AND RESULTS: We studied 5468 participants of the Multi-Ethnic Study of Atherosclerosis, composed of white, Chinese, Hispanic, and black participants with an average age of 61.9 years (47.8% men) and who were free of coronary heart disease at baseline. Manual-traced and edge-detected IMT measurements were made in the same location on ultrasound images of the right common carotid artery far wall in an area free of plaque. Manual-traced and edge-detected common carotid artery IMT measurements were added separately to multivariable Cox proportional hazards models with time to incident coronary heart disease as the outcome and adjusted for traditional coronary heart disease Framingham risk factors, lipid-lowering therapy, blood pressure-lowering therapy, and race or ethnicity. Additional models were generated after adding clinic site and reader. There were 349 events during a median follow-up of 10.2 years. In adjusted models, the hazard ratio was not significant (1.31; 95% CI 0.84 to 2.06) for each millimeter increase in manual-traced IMT but was significant for edge-detected IMT (hazard ratio 1.63; 95% CI 1.12 to 2.37). Edge-detected IMT remained statistically associated with outcomes after additional adjustment for clinic site and reader performing the IMT measurement (hazard ratio 1.59; 95% CI 1.07 to 2.35). CONCLUSIONS: Edge-detected common carotid artery far wall IMT has similar if not stronger associations with coronary heart disease outcomes when compared with manual-traced IMT. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov/. Unique identifier: NCT00063440.
No takes yet. Share an insight, caveat, or question.
Polak et al. (2015) conducted a cohort in Incident coronary heart disease (n=5,468). Edge-detected common carotid artery intima-media thickness (IMT) vs. Manual-traced IMT was evaluated on Incident coronary heart disease (HR 1.63, 95% CI 1.12 to 2.37). Edge-detected common carotid artery IMT was associated with incident coronary heart disease, whereas manual-traced IMT was not.
Synapse has enriched 10 related papers. Consider them for comparative context: