Key result
His-bundle pacing linked to improved RV fractional area change and global longitudinal strain versus RVP.
Why the study?
His-bundle pacing is an emerging physiological pacing technique, but its effects on right ventricular performance were unknown.
Does His-Bundle pacing improve right ventricular performance compared to apical right ventricular pacing in patients undergoing permanent pacemaker implantation?
Observational (n=84)
Does His-Bundle pacing improve right ventricular performance compared to apical right ventricular pacing in patients undergoing permanent pacemaker implantation?
His-bundle pacing preserves and improves right ventricular echocardiographic performance at 6 months compared to apical right ventricular pacing, which causes deterioration.
May support His-bundle over apical pacing for RV preservation; hypothesis-generating pending randomized outcome trials.
BACKGROUND: His-Bundle pacing (HBP) is an emerging technique for physiological pacing. However, its effects on right ventricle (RV) performance are still unknown. METHODS: We enrolled consecutive patients with an indication for pacemaker (PM) implantation to compare HBP versus RV pacing (RVP) effects on RV performance. Patients were evaluated before implantation and after 6 months by a transthoracic echocardiogram. RESULTS: A total of 84 patients (age 75.1±7.9 years, 64% male) were enrolled, 42 patients (50%) underwent successful HBP, and 42 patients (50%) apical RVP. At follow up, we found a significant improvement in RV-FAC (Fractional Area Change)% [baseline: HBP 34 IQR (31-37) vs. RVP 33 IQR (29.7-37.2),p = .602; 6-months: HBP 37 IQR (33-39) vs. RVP 30 IQR (27.7-35), p < .0001] and RV-GLS (Global Longitudinal Strain)% [baseline: HBP -18 IQR (-20.2 to -15) vs. RVP -16 IQR (-18.7 to -14), p = .150; 6-months: HBP -20 IQR(-23 to -17) vs. RVP -13.5 IQR (-16 to -11), p < .0001] with HBP whereas RVP was associated with a significant decline in both parameters. RVP was also associated with a significant worsening of tricuspid annular plane systolic excursion (TAPSE) (p < .0001) and S wave velocity (p < .0001) at follow up. Conversely from RVP, HBP significantly improved pulmonary artery systolic pressure (PASP) [baseline: HBP 38 IQR (32-42) mmHg vs. RVP 34 IQR (31.5-37) mmHg,p = .060; 6-months: HBP 32 IQR (26-38) mmHg vs. RVP 39 IQR (36-41) mmHg, p < .0001] and tricuspid regurgitation (p = .005) irrespectively from lead position above or below the tricuspid valve. CONCLUSIONS: In patients undergoing PM implantation, HBP ensues a beneficial and protective impact on RV performance compared with RVP.
No takes yet. Share an insight, caveat, or question.
Grieco et al. (2021) conducted an observational in Indication for pacemaker implantation (n=84). His-Bundle pacing (HBP) vs. Apical right ventricle pacing (RVP) was evaluated on Right ventricular performance (RV-FAC %) (p=<0.0001). His-Bundle pacing significantly improved right ventricular fractional area change (median 37% vs 30%, p<0.0001) and global longitudinal strain compared to right ventricular pacing at 6 months.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: