Key result
Spontaneous ventricular ectopic beats occurred at similar frequencies across dogs, minipigs, and non-human primates, though dogs exhibited more frequent junctional complexes and AV blocks.
Why the study?
Characterizing the incidence of spontaneous arrhythmias to identify possible drug-related effects is an important component of analysis in safety pharmacology studies using telemetry.
What is the incidence of spontaneous arrhythmias in non-clinical species with and without telemetry transmitters?
Observational (n=317)
Yes
What is the incidence of spontaneous arrhythmias in non-clinical species with and without telemetry transmitters?
Characterization of spontaneous arrhythmias in preclinical species shows similar ventricular ectopic beat frequencies but higher junctional complexes and AVB in dogs, informing safety pharmacology study design.
Answers are grounded in this paper and cite their sources.
May guide species selection for arrhythmia safety studies; leaves open translation to clinical monitoring.
INTRODUCTION: Characterization of the incidence of spontaneous arrhythmias to identify possible drug-related effects is often an important part of the analysis in safety pharmacology studies using telemetry. METHODS: A retrospective analysis in non-clinical species with and without telemetry transmitters was conducted. Electrocardiograms (24 h) from male and female beagle dogs (n = 131), Göttingen minipigs (n = 108) and cynomolgus non-human primates (NHP; n = 78) were analyzed. RESULTS: Ventricular tachycardia (VT) was observed in 3% of the dogs but was absent in minipigs and NHPs. Ventricular fibrillation (VF) was not observed in the 3 species. Ventricular premature beats (VPBs) were more frequent during daytime and atrioventricular blocks (AVBs) were more frequent at night in all species. A limited number of animals exhibited a high arrhythmia frequency and there was no correlation between animals with higher frequency of an arrhythmia type and the frequency of other arrythmias in the same animals. Clinical chemistry or hematology parameters were not different with or without telemetry devices. NHP with a transmural left ventricular pressure (LVP) catheter exhibited a greater incidence of VPBs and PJCs compared to telemetry animals without LVP. DISCUSSION: All species were similar with regards to the frequency of ventricular ectopic beats (26-46%) while the dog seemed to have more frequent junctional complexes and AVB compared to NHP and minipigs. Arrhythmia screening may be considered during pre-study evaluations, to exclude animals with abnormally high arrhythmia incidence.
No takes yet. Share an insight, caveat, or question.
Boulay et al. (2023) conducted an observational in Spontaneous arrhythmias (n=317). Telemetry transmitters vs. No telemetry transmitters was evaluated on Incidence of spontaneous arrhythmias. Spontaneous ventricular ectopic beats occurred at similar frequencies across dogs, minipigs, and non-human primates, though dogs exhibited more frequent junctional complexes and AV blocks.