Key result
Commercial cardiac troponin assays exhibited different species-specific responses in animals with induced myocardial injury, requiring individual assay characterization by species.
Not all commercial cardiac troponin assays are suitable for monitoring troponin in each animal species, highlighting the need for individual assay characterization in preclinical studies.
Troponin assays require species-specific validation before preclinical use; leaves open reliable biomarker translation across animal cardiovascular models.
BACKGROUND: Information is needed regarding analytical characteristics of cardiac troponin (cTn) assays used in preclinical studies. METHODS: We measured cTnI and cTnT in serum from normal animals and animals with induced myocardial injury [Sprague-Dawley (SD) and Wistar rats, beagle dogs, and rhesus (Rh) and cynomolgus (Cy) monkeys]. We evaluated the following assays: for cTnI, Abbott Architect, Bayer Centaur (first and second generation), Beckman Access, DPC Immulite, Dade Dimension, Ortho Vitros ES, Tosoh AIA, and species-specific enzyme immunoassays; for cTnT, Roche Elecsys. RESULTS: We found different species-specific responses for the troponin assays evaluated. Abbott, Bayer Ultra, Beckman, and Dade assays gave good responses across all species. In rats, weak responses were observed with DPC and Ortho, and no measurable response with Tosoh. In dogs, weak responses were observed with Tosoh cTnI, Roche cTnT, and species-specific cTnI. In cynomolgus monkeys, weak responses were observed with species-specific cTnI and Roche cTnT. Assay imprecision was < or = 20% at 3 or more examined cTn concentrations for Beckman (rat, dog, monkey), Dade (rat, dog, monkey), Abbott (rat, dog, monkey), Bayer first generation (dog), Bayer Ultra (rat, dog, monkey), Roche (monkey), DPC (dog, monkey), Ortho (dog, monkey), and Tosoh (dog, monkey) assays, whereas imprecision was < or = 20% at 2 or fewer concentrations for the Bayer first generation (rat, monkey), Roche cTnT (rat, dog), and DPC (rat) assays. CONCLUSIONS: Not all cTn assays are suitable for monitoring cTn in each animal species or strain. Individual assay characterization by animal species is needed to prevent misinterpretation of myocardial injury-based cardiac troponin findings.
No takes yet. Share an insight, caveat, or question.
Apple et al. (2008) studied Induced acute myocardial injury. Commercial cardiac troponin I and T immunoassays was evaluated on Analytical characteristics (species-specific responses and imprecision). Commercial cardiac troponin assays exhibited different species-specific responses in animals with induced myocardial injury, requiring individual assay characterization by species.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: