Key result
Far-field to near-field EGM intervals from stored ICD events differentiated anteroseptal (31 ± 13 ms) from inferolateral VT origin in nonischemic cardiomyopathy.
Why the study?
The majority of NICM patients present perivalvular substrates that are predominantly anteroseptal or inferolateral, and the relative timing of stored ICD electrograms may distinguish between these VT origins.
Does the relative timing of far-field and near-field EGMs from stored ICD events differentiate antero-septal from infero-lateral origin of ventricular tachycardia in patients with nonischemic cardiomyopathy?
Observational (n=48)
Does the relative timing of far-field and near-field EGMs from stored ICD events differentiate antero-septal from infero-lateral origin of ventricular tachycardia in patients with nonischemic cardiomyopathy?
The relative timing of far-field and near-field EGMs from stored ICD events can help differentiate antero-septal from infero-lateral VT origin in patients with nonischemic cardiomyopathy.
Answers are grounded in this paper and cite their sources.
May aid VT origin localization from ICD EGMs in nonischemic cardiomyopathy; hypothesis-generating and requires prospective validation.
INTRODUCTION: The majority of patients with nonischemic cardiomyopathy (NICM) present a perivalvular substrate that is either predominantly antero-septal (AS) or infero-lateral (IL), corresponding to specific ventricular tachycardia (VT) morphologies. The relative timing of far-field and near-field ventricular electrograms (EGMs) from stored implantable cardioverter-defibrillator (ICD) events of VT may be used to distinguish AS from IL VT in NICM. METHODS AND RESULTS: We analyzed 48 patients with NICM with either a primarily AS (54%) or IL (56%) VT source undergoing catheter ablation between 2003 and 2018. Only patients with retrievable ICD-EGMs of spontaneous VT events which could be matched with VTs induced during the ablation procedure were included. A total of 56 VT events (52% AS origin and 48% IL origin) were analyzed, yielding a mean far-field to near-field interval of 31 ± 13 milliseconds for AS VTs and 47 ± 19 milliseconds for IL VTs (P = .001). At receiver operating characteristic analysis (AUC = 0.734), a far-field to near-field interval of ≥ 60 milliseconds ruled out AS VTs in 29 (100%) cases and diagnosed IL VTs with a positive predictive value (PPV) of 100% and a negative predictive value (NPV) of 63%. An interval of ≤ 20 milliseconds ruled out IL VTs in 25 (93%) cases and diagnosed AS VTs with a PPV of 83% and NPV of 57%. Significant overlap between the two groups was observed among far-field to near-field intervals in between 20 milliseconds and 60 milliseconds. CONCLUSIONS: The relative timing of far-field and near-field EGMs from stored clinical ICD events of VT can be helpful to differentiate AS vs IL origin of VT in NICM.
No takes yet. Share an insight, caveat, or question.
Kodali et al. (2019) conducted an observational in Nonischemic cardiomyopathy with ventricular tachycardia (n=48). Far-field to near-field ventricular electrogram timing vs. Antero-septal vs infero-lateral VT origin was evaluated on Mean far-field to near-field interval (p=.001). Far-field to near-field EGM intervals from stored ICD events differentiated anteroseptal (31 ± 13 ms) from inferolateral VT origin in nonischemic cardiomyopathy.