Key result
Cardiac resynchronization therapy (CRT-D) improved psycho-cognitive performance, including DemTect scores and depression, compared to ICD therapy in CHF patients.
Why the study?
Does biventricular defibrillator (CRT-D) improve psycho-cognitive performance and depression symptoms in patients with congestive heart failure and severe left ventricular dysfunction compared to implantable single or dual-chamber defibrillator (ICD)?
Cohort (n=74)
Single-blind
Does biventricular defibrillator (CRT-D) improve psycho-cognitive performance and depression symptoms in patients with congestive heart failure and severe left ventricular dysfunction compared to implantable single or dual-chamber defibrillator (ICD)?
Cardiac resynchronization therapy significantly improves psycho-cognitive performance and depression symptoms in patients with heart failure and severe left ventricular dysfunction compared to standard ICD therapy.
Answers are grounded in this paper and cite their sources.
CRT-D may confer psycho-cognitive benefits in heart failure; hypothesis-generating from observational data and requires randomized confirmation.
BACKGROUND: Reduced cognitive performance and high prevalence of depression have been reported in patients with congestive heart failure (CHF) and severe left ventricular dysfunction. However, effects of contemporary device therapy on cognitive performance and depression symptoms have not been studied thoroughly. METHODS: Seventy-four consecutive CHF patients-45 receiving a biventricular defibrillator (CRT-D) and 29 receiving an implantable single or dual-chamber defibrillator (ICD) as a control group-were enrolled in this investigator-initiated, prospective, controlled, and investigator-blinded study. A set of neuropsychological tests (mini-mental state examination, DemTect, age-concentration test, and Beck depression inventory) was performed before, at 3 and at 6 months after device implantation. RESULTS: DemTect-score improved significantly (F = 7.8; P = 0.007) after CRT-D-implantation compared with ICD. Age-concentration test revealed better concentration ability after CRT-D-implantation (F = 8.3; P = 0.005) compared with ICD. Under CRT-D mini-mental state examination showed a significant improvement (F = 4.2; P = 0.043). CRT with defibrillator therapy also improved depression revealed by beck depression inventory (F = 14.7; P< 0.001) compared with ICD. CONCLUSION: This prospective study is the first to demonstrate psycho-cognitive improvement by resynchronization therapy in CHF patients with severe left ventricular dysfunction. In contrast to ICD therapy, the beneficial effect of CRT-D on psycho-cognitive performance might be attributed to improved cardiac function and haemodynamics.
No takes yet. Share an insight, caveat, or question.
Duncker et al. (2015) conducted a cohort in Congestive heart failure (CHF) and severe left ventricular dysfunction (n=74). Biventricular defibrillator (CRT-D) vs. Implantable single or dual-chamber defibrillator (ICD) was evaluated on DemTect-score (p=0.007). Cardiac resynchronization therapy (CRT-D) improved psycho-cognitive performance, including DemTect scores and depression, compared to ICD therapy in CHF patients.
Synapse has enriched 10 related papers. Consider them for comparative context: