Key result
Iopromide-protaxel injection reduces neointimal area ~34% after coronary stenting in a porcine model.
Why the study?
Lipophilic taxanes can be dissolved in contrast media at higher concentrations than saline, suggesting contrast media may serve as a matrix for local antiproliferative drug delivery to prevent restenosis after coronary stenting.
Does a taxane-contrast agent formulation reduce in-stent restenosis in a porcine coronary stent model?
Does a taxane-contrast agent formulation reduce in-stent restenosis in a porcine coronary stent model?
Answers are grounded in this paper and cite their sources.
Using a contrast agent as a solvent for a taxane provides a novel local drug delivery mechanism that successfully inhibits in-stent restenosis in a porcine model.
BACKGROUND: Lipophilic taxanes can be dissolved in contrast media at significantly higher concentration than in saline. As contrast media have occasionally been observed to delineate the contour of coronary arteries for some seconds they may serve as a matrix for an antiproliferative drug aimed at preventing restenosis. The aim of this study was to test a novel taxane-contrast agent formulation for this new approach in the setting of coronary stenting. METHODS AND RESULTS: In cell culture experiments (bovine vascular smooth muscle cells), 60-min incubation with contrast agent-taxane formulations (iopromide-paclitaxel, iopromide-protaxel) induced a significant, concentration-dependent inhibition of vascular smooth muscle cell (VSMC) proliferation over 12 days. Shorter incubation times of 10 and 3 min showed the same efficacy. For in vivo investigation, 16 stents were implanted into the coronary arteries of eight pigs using a 1.3 to 1 overstretch ratio. A control group received iopromide 370 alone while the treatment group was injected with a iopromide-protaxel formulation at a dose of 74 micromol/l, which is far below protaxel levels inducing systemic toxicity. Quantitative angiography and histomorphometry of the stented arteries asserted statistic equality of the baseline parameters between the control and treatment groups. After 28 days, the treatment group showed a marked reduction of the parameters characterizing in-stent restenosis, especially a 34% reduction of the neointimal area. CONCLUSIONS: First evidence is provided that using a contrast agent as solvent for a taxane constitutes a new drug delivery mechanism able to inhibit in-stent restenosis in the porcine restenosis model.
No takes yet. Share an insight, caveat, or question.
Bruno Scheller (2003) studied in-stent restenosis (n=8). iopromide-protaxel formulation vs. iopromide 370 alone was evaluated on neointimal area (34% reduction). Injection of an iopromide-protaxel formulation during coronary stenting in a porcine model reduced the neointimal area by 34% at 28 days compared to iopromide alone.
Synapse has enriched 10 related papers. Consider them for comparative context: