Key result
Simultaneous atrioventricular pacing (SAVP) resulted in higher atrial fibrillation inducibility compared to rapid ventricular pacing in a canine model.
Why the study?
Does simultaneous atrioventricular pacing (SAVP) induce more reproducible sustained AF and atrial remodeling compared to rapid ventricular pacing (RVP) in a canine model?
RCT (n=44)
randomized
Does simultaneous atrioventricular pacing (SAVP) induce more reproducible sustained AF and atrial remodeling compared to rapid ventricular pacing (RVP) in a canine model?
The SAVP canine model induces profound mechanical and substrate atrial remodeling and reproducible sustained AF, offering a clinically relevant model for testing AF interventions.
Answers are grounded in this paper and cite their sources.
SAVP may offer a reproducible canine AF model for intervention testing; leaves open translation to human pacing.
Rapid ventricular pacing (RVP) is a well-established animal model of atrial fibrillation (AF). However, this model is limited by a high mortality rate and severe heart failure. The purpose of our study was to assess a new canine model of inducible AF. We performed acute, short-term, simultaneous atrioventricular pacing (SAVP) and RVP (in random order) in 14 dogs for 30 s. SAVP produced more echocardiographic pulmonary venous flow reversal, a greater increase in mean pulmonary capillary wedge pressure, and a significantly greater decrease in left atrial emptying function (-84.4 +/- 38.6% vs. -23.7 +/- 27.1%, P < 0.05) than RVP. Thirty dogs were randomized to three, longer-term, study groups: eight dogs in the control group (no pacing), eight dogs in the RVP group (2 wk at 240 beats/min followed by 3 wk at 220 beats/min), and fourteen dogs in the SAVP group (2 wk at 220 beats/min). SAVP induced less left ventricular dysfunction but more left atrial dysfunction than RVP. SAVP dogs had similar atrial effective refractory periods as RVP dogs but more heterogeneity in conduction and more AF inducibility (83% vs. 40%, P < 0.05) and maintenance (median 1,660 vs. 710 s, P < 0.05) than RVP dogs. SAVP induced more collagen turnover and was associated with a significantly greater increase in type III collagen in the atria compared with RVP dogs (6.9 +/- 1.5 vs. 4.8 +/- 1.6, respectively, P < 0.05 vs. 1.1 +/- 0.7 in unpaced control dogs). In conclusion, the SAVP model induced profound mechanical and substrate atrial remodeling and reproducible sustained AF. This new model is clinically relevant and may be useful for testing AF interventions.
No takes yet. Share an insight, caveat, or question.
Laurent et al. (2008) conducted an RCT in Atrial fibrillation (canine model) (n=44). Simultaneous atrioventricular pacing (SAVP) vs. Rapid ventricular pacing (RVP) and unpaced control was evaluated on Atrial fibrillation inducibility (p=<0.05). Simultaneous atrioventricular pacing (SAVP) resulted in higher atrial fibrillation inducibility compared to rapid ventricular pacing in a canine model.