Key result
Mitral annuloplasty ring dehiscence was more common among rigid rings compared to semi-rigid and flexible rings.
Why the study?
Mitral and tricuspid ring annuloplasty dehiscence is a rare but challenging procedural failure with multifactorial incidence and predisposing risk factors.
Does the type of annuloplasty ring affect the rate of ring dehiscence in patients undergoing mitral or tricuspid valve repair?
Systematic Review (n=10,340)
Does the type of annuloplasty ring affect the rate of ring dehiscence in patients undergoing mitral or tricuspid valve repair?
Mitral annuloplasty ring dehiscence is a rare complication (1.43%) but is significantly more common with rigid rings and in patients with ischemic mitral regurgitation.
Answers are grounded in this paper and cite their sources.
Rigid rings raise dehiscence risk after mitral repair; extends evidence on ring selection and supports randomized comparisons of ring types.
OBJECTIVES: Mitral and tricuspid ring annuloplasty dehiscence with consequent recurrent valve regurgitation is a rare but challenging procedural failure. The incidence and predisposing risk factors for annuloplasty ring dehiscence include technical and pathological ones. METHODS: A systematic database search with pooled analysis was conducted of original articles that only included dehiscence rate of mitral and tricuspid ring in EMBASE, MEDLINE, Cochrane database and Google Scholar, from inception to November 2020. The outcomes included were dehiscence rate in mitral and tricuspid, type of ring implanted, dehiscence rate by pathology and by ring size and shape. RESULTS: Our search yielded 821 relevant studies. Thirty-three studies met the inclusion criteria with a total of 10 340 patients (6543 mitral, 1414 tricuspid) of which 87 (mitral) and 30 (tricuspid) had dehiscence. Overall, dehiscence rate was 1.43%, diagnosed at a median of 4.5 ± 1.0 months postoperatively. A significant difference in mitral dehiscence rate was found by ring type (semi-rigid 1.86%, rigid 2.32%; flexible 0.43%; P < 0.001). There was no significant difference in rate of dehiscence by ring size (P = 0.067) and shape in mitral (P = 0.281) but there was higher dehiscence rate in ischaemic compared to non-ischaemic mitral regurgitation (3.91% vs 1.63%; P = 0.022). Among tricuspid studies, 9 of 10 studies did not report any dehiscence. CONCLUSIONS: Although rigid, semi-rigid and flexible annuloplasty rings provide acceptable valve repair outcomes, mitral annuloplasty ring dehiscence is clinically more common among rigid rings. Understanding the multifactorial nature of ring dehiscence will help in identifying the patients at high risk and improve their clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Rad et al. (2021) conducted a systematic review in Mitral and tricuspid valve regurgitation (n=10,340). Rigid annuloplasty ring vs. Flexible annuloplasty ring was evaluated on Mitral annuloplasty ring dehiscence rate (p=<0.001). Mitral annuloplasty ring dehiscence was more common among rigid rings compared to semi-rigid and flexible rings.
Synapse has enriched 10 related papers. Consider them for comparative context: