Why the study?
Can left ventricular volume parameters measured on prospectively triggered 64-slice MDCT accurately detect left ventricular systolic dysfunction?
Can left ventricular volume parameters measured on prospectively triggered 64-slice MDCT accurately detect left ventricular systolic dysfunction?
Left ventricular volume parameters, particularly LVESV, measured on prospectively triggered MDCT have high accuracy for detecting left ventricular systolic dysfunction, potentially reducing radiation exposure by avoiding retrospective imaging.
MDCT LV volumes detect LVSD with high specificity; leaves open routine adoption versus echocardiography pending validation.
In this study, we define the correlation between LV volumes (both LV end-diastolic volume [LVEDV] and LV end-systolic volume [LVESV]) and ejection fraction (EF) on 64 slice multi-detector computed tomography (MDCT). We also determine the accuracy of all the LV volume (LVV) parameters to detect LV systolic dysfunction (LVSD) and investigate the feasibility of using LVV as a surrogate of LVSD on prospectively gated imaging to prevent the radiation exposure of retrospective imaging. 568 patients undergoing 64-detector MDCT were divided into 2 groups: Group 1-subjects without any heart disease and LVEF ≥ 50%; and Group 2-patients with coronary artery disease and LVEF < 50% (defined as LVSD). The LVV (LV cavity only) and Total LV volume (cavity + LV mass) at end-systole and end-diastole (LVESV, Total LVESV, LVEDV and Total LVEDV) were measured. The upper limit values (mean + 2 SD) of all LVV parameters in Group 1 were used as the reference criterion to diagnose LVSD in Group 2. An exponential correlation was found between LVEF and all the LVV parameters. The specificity to detect LVSD in Group 2 was >90% and the sensitivity was 88.9, 83.3, 61.3 and 74.9% by using LVESV, Total LVESV, LVEDV and Total LVEDV, respectively. Systolic and diastolic LV volumes had a high correlation with LVEF and a high accuracy to detect LVSD. Thus, on prospectively triggered imaging, ventricular volumes can predict patients with reduced LVEF, and appropriate referrals can be made.
No takes yet. Share an insight, caveat, or question.
Gupta et al. (2010) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: