Why the study?
Does positioning the atrial electrode on the atrial septum compared to the right atrial appendage alter hemodynamics during AV sequential pacing in patients without heart failure?
Population
21 patients (4 male, 17 female) aged 49 +/- 15 years without heart failure.
Comparison
Atrioventricular sequential pacing with the… vs Atrioventricular sequential pacing with the…
Design
Other
Authors
Loading...
No stroke volume difference with septal versus appendage pacing in non-HF patients; leaves open site selection effects in HF.
Does positioning the atrial electrode on the atrial septum compared to the right atrial appendage alter hemodynamics during AV sequential pacing in patients without heart failure?
Altering the left AV interval by changing the atrial pacing site from the right atrial appendage to the atrial septum has minimal hemodynamic effect on stroke volume in patients without heart failure.