Key result
Right atrial septal pacing reversed atrial mechanical timing to a left-to-right sequence and required a shorter optimal left heart AV delay than conventional pacing (108 vs 152 ms, P=0.002).
Why the study?
Does right atrial septal pacing alter the interatrial contraction sequence compared to conventional right atrial pacing?
Population
Patients undergoing atrial pacing, including a subset with high degree atrioventricular block.
Comparison
Right atrial septal pacing vs Conventional right atrial pacing, atrial…
Design
Cohort
Authors
Loading...
May warrant shorter AV delays with septal leads in dual-chamber pacing; leaves open outcome benefits in observational data.
Does right atrial septal pacing alter the interatrial contraction sequence compared to conventional right atrial pacing?
Absolute Event Rate: 108% vs 152%
p-value: p=0.002
Interatrial septal pacing reverses the atrial mechanical timing to a left-to-right contraction sequence rather than synchronizing right and left atrial contractions, requiring shorter AV delays during dual chamber pacing.
Kindermann et al. (2000) studied High degree atrioventricular (AV) block (n=59). Right atrial septal pacing vs. Conventional right atrial pacing was evaluated on Optimal left heart AV delay (p=0.002). Right atrial septal pacing reversed atrial mechanical timing to a left-to-right sequence and required a shorter optimal left heart AV delay than conventional pacing (108 vs 152 ms, P=0.002).