Key result
Dual-site right atrial pacing at an AV interval of 100 ms improved left atrial mechanical function, yielding higher peak A wave velocity than high RA pacing.
Why the study?
Does dual-site right atrial pacing with varying AV intervals improve left atrial mechanical function compared to high right atrial pacing in patients with dual-site RA pacemakers?
RCT (n=9)
Random order
Does dual-site right atrial pacing with varying AV intervals improve left atrial mechanical function compared to high right atrial pacing in patients with dual-site RA pacemakers?
The optimal AV interval for left atrial mechanical function during dual-site RA pacing is significantly shorter (100 ms) than during standard high RA pacing.
Answers are grounded in this paper and cite their sources.
Optimizing AV interval to 100 ms during dual-site RA pacing improves LA function; extends AF prevention data to mechanical endpoints.
Recent studies have suggested that dual-site right atrial (RA) pacing via the high RA and coronary sinus ostium (CSos) prevents atrial fibrillation (AF). However, the programming of the atrioventricular (AV) interval associated with optimal left atrial (LA) mechanical function during high RA and dual-site RA pacing has not been defined. LA mechanical function was studied by measuring transmitral pulsed Doppler echocardiographic peak A wave velocity and percent A wave filling, in six women and three men, 67 +/- 8 years of age, who had received dual-site RA pacemakers in a randomized study. Serial echocardiographic measurements were performed during high RA or dual-site RA pacing at 80 beats/min with AV intervals of 50, 100, 150, or 200 ms tested in random order. High RA and dual-site RA pacing at an AV interval of 50 ms were associated with significantly lower peak A wave velocity and percent A wave filling, compared to the other AV intervals (all P < 0.05). Compared with high RA pacing, dual-site RA pacing was associated with significantly higher peak A wave velocity (85 +/- 12 vs 72 +/- 17 cm/s, P = 0.04) and percent A wave filling (24 +/- 3 vs 20 +/- 4%, P = 0.02) at an AV interval of 100 ms, but a lower peak A wave velocity at an AV interval of 200 ms (77 +/- 10 vs 84 +/- 8 cm/s, P = 0.004). In conclusion, variations in the AV interval during atrial pacing have significant effects on LA function. As a consequence of altered atrial activation, the AV interval associated with optimal LA mechanical function during dual-site RA pacing was significantly shorter than that during RA pacing. This observation has important implications with respect to the programming of dual-site RA pacemakers implanted to prevent AF for hemodynamic purpose.
No takes yet. Share an insight, caveat, or question.
HO et al. (2000) conducted an RCT in Patients with dual-site right atrial pacemakers (n=9). Dual-site right atrial pacing vs. High right atrial pacing was evaluated on Peak A wave velocity at an AV interval of 100 ms (p=0.04). Dual-site right atrial pacing at an AV interval of 100 ms improved left atrial mechanical function, yielding higher peak A wave velocity than high RA pacing.