Why the study?
Does coronary balloon occlusion or rapid pacing induce right ventricular stunning and dysfunction in humans?
Does coronary balloon occlusion or rapid pacing induce right ventricular stunning and dysfunction in humans?
Answers are grounded in this paper and cite their sources.
Both rapid pacing during TAVR and right coronary artery balloon occlusion during PCI induce acute and sustained right ventricular stunning and dysfunction, which may have intraoperative implications for patients lacking right ventricular reserve.
Background We sought to determine whether right ventricular stunning could be detected after supply (during coronary balloon occlusion [ BO ]) and supply/demand ischemia (induced by rapid pacing [ RP ] during transcatheter aortic valve replacement) in humans. Methods and Results Ten subjects with single‐vessel right coronary artery disease undergoing percutaneous coronary intervention with normal ventricular function were studied in the BO group. Ten subjects undergoing transfemoral transcatheter aortic valve replacement were studied in the RP group. In both, a conductance catheter was placed into the right ventricle, and pressure volume loops were recorded at baseline and for intervals over 15 minutes after a low‐pressure BO for 1 minute or a cumulative duration of RP for up to 1 minute. Ischemia‐induced diastolic dysfunction was seen 1 minute after RP (end‐diastolic pressure [mm Hg]: 8.1±4.2 versus 12.1±4.1, P <0.001) and BO (end‐diastolic pressure [mm Hg]: 8.1 ± 4.0 versus 8.7±4.0, P =0.03). Impairment of systolic and diastolic function after BO remained at 15‐minutes recovery (ejection fraction [%]: 55.7±9.0 versus 47.8±6.3, P <0.01; end‐diastolic pressure [mm Hg]: 8.1±4.0 versus 9.2±3.9, P <0.01). Persistent diastolic dysfunction was also evident in the RP group at 15‐minutes recovery (end‐diastolic pressure [mm Hg]: 8.1±4.1 versus 9.9±4.4, P =0.03) and there was also sustained impairment of load‐independent indices of systolic function at 15 minutes after RP (end‐systolic elastance and ventriculo‐arterial coupling [mm Hg/mL]: 1.25±0.31 versus 0.85±0.43, P <0.01). Conclusions RP and right coronary artery balloon occlusion both cause ischemic right ventricular dysfunction with stunning observed later during the procedure. This may have intraoperative implications in patients without right ventricular functional reserve.
No takes yet. Share an insight, caveat, or question.
Axell et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: