Why the study?
Does intravenous infusion of nitroprusside, nitroglycerin, or phentolamine alter cardiac dynamics and systemic arteriovenous shunting in nonanesthetized dogs?
Does intravenous infusion of nitroprusside, nitroglycerin, or phentolamine alter cardiac dynamics and systemic arteriovenous shunting in nonanesthetized dogs?
Intravenous infusion of nitroprusside, nitroglycerin, or phentolamine alters cardiac dynamics but does not modify total systemic arteriovenous shunting in nonanesthetized dogs.
Stable shunting with vasodilators in dogs; leaves open translation to human cardiac output distribution.
The effects of nitroprusside, nitroglycerin and phentolamine on cardiac dynamics and on the fraction of cardiac output shunted through systemic arteriovenous communications, which may explain disparate responses elicited by these systemic vasodilators upon venous return, have been studied in 15 nonanesthetized dogs. Cardiac dynamic parameters were measured by electromagnetic flow probe placed at the root of the aorta. Quantitative measurements of total systemic arteriovenous shunting were determined from the fraction of 9 mu radioactively labeled microspheres, injected into the left atrium, recovered in the pulmonary artery. To provide a common basis for comparison, the mean arterial pressure was lowered by 15-20% either with an intravenous infusion of nitroprusside, nitroglycerin or phentolamine. At the fifteenth minute of infusion, nitroprusside produced significant decrease in stroke volume index (23%) and left ventricular power and work (28% and 40%). Nitroglycerin decreased significantly stroke volume index (12%), cardiac index (9%) and left ventricular work (22%). Phentolamine significantly increased heart rate (72%) and left ventricular maximum acceleration (30%) while it decreased stroke volume index (41%), left ventricular power and work (19% and 55%). Total peripheral resistance was significantly affected only by infusion of phentolamine (-18%). Left ventricular maximum velocity, mean systolic ejection rate and maximum systolic flow did not change significantly under infusion of these systemic vasodilators. Under control conditions, total systemic shunting of cardiac output averaged 8.9-10% and was not modified by any of the vasodilators used. Arteriovenous O2 difference and oxygen consumption, corroborated these findings since they remained within normal limits before and after infusion of nitroprusside, nitroglycerin or phentolamine.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Dumont et al. (1984) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: