Key result
Bright-blood cine MR imaging enabled direct visualization of the pulmonary valve in all subjects, with leaflet signal-to-noise ratios differing from blood.
Why the study?
Does bright-blood cine MR imaging allow for direct visualization and functional evaluation of the pulmonary valve in normal subjects and patients after Ross operation?
Observational (n=24)
Does bright-blood cine MR imaging allow for direct visualization and functional evaluation of the pulmonary valve in normal subjects and patients after Ross operation?
Cine MR imaging is a feasible and effective modality for the in-plane visualization and morphological/functional evaluation of the pulmonary valve, including in patients who have undergone a Ross operation.
Answers are grounded in this paper and cite their sources.
Supports feasibility of bright-blood cine MR for pulmonary valve assessment post-Ross; leaves open prospective validation before clinical adoption.
PURPOSE: To evaluate the capability of bright-blood cine MR to directly visualize the leaflets of the valve replacement in pulmonary position following Ross operation. MATERIAL AND METHODS: Long and short axis views of the pulmonary valve were obtained in 10 normal subjects and 14 patients after Ross operation. Valve morphology and function were analyzed and signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Flow measurements were performed in the pulmonary trunk to assess pulmonary regurgitation. RESULTS: In all subjects, tricuspid morphology of the pulmonary valve was visualized. SNR of the leaflets in normal subjects (9.8 +/- 3.0) and in patients after Ross operation (7.5 +/- 2.2) differed significantly from blood (12.6 +/- 3.2 and 11.3 +/- 2.5, respectively, p < 0.05). Valvular regurgitation was seen in 5 patients as an insufficient closure of the valve which was confirmed by flow measurements. CONCLUSION: Cine MR enables in-plane visualization of the pulmonary valve and allows for functional and morphological evaluation in patients after pulmonary valve surgery.
No takes yet. Share an insight, caveat, or question.
Kivelitz et al. (2003) conducted an observational in Pulmonary valve replacement (Ross operation) (n=24). Bright-blood cine MR imaging was evaluated on Visualization of valve morphology and signal-to-noise ratio (SNR) of the leaflets (p=<0.05). Bright-blood cine MR imaging enabled direct visualization of the pulmonary valve in all subjects, with leaflet signal-to-noise ratios differing from blood.
Synapse has enriched 10 related papers. Consider them for comparative context: