Key result
Cine-MR imaging demonstrated high diagnostic accuracy for valvular regurgitation compared to cineangiography, with sensitivities of 93.5% for MR, 100% for AR, and 85.7% for TR.
Why the study?
Does cine-MR imaging accurately evaluate the severity of valvular regurgitation compared to cineangiography in patients with valvular disease?
Observational (n=104)
Does cine-MR imaging accurately evaluate the severity of valvular regurgitation compared to cineangiography in patients with valvular disease?
Cine-MR imaging is a highly sensitive and specific noninvasive method for identifying and semiquantitatively assessing the severity of valvular regurgitation.
Answers are grounded in this paper and cite their sources.
Supports cine-MR for noninvasive valvular regurgitation assessment; leaves open prospective validation versus echocardiography.
It is well known that the regurgitant blood flow of valvular disease shows a low intensity signal (LS) in cine-MR imaging (cMRI). To determine the significance of cMRI in evaluation of valvular regurgitation, 104 patients who had been assessed by cineangiography also underwent oblique cMRI for mitral regurgitation (MR) and aortic regurgitation (AR), and transverse cMRI for tricuspid regurgitation (TR). In evaluating the accuracy of diagnosis of valvular regurgitation on the basis of the presence of LS in the recipient chamber, sensitivity was found to be 93.5% for MR, 100% for AR and 85.7% for TR; specificity was 76.9% for MR and 100% for AR. The length and area of LS were planimetered in any view with the largest area, and its ratios to the length and area of the recipient chamber of view were calculated. Each index was significantly higher than the degree calculated by cineangiography. The best correlation with angiography was the ratio of the area of LS to the recipient chamber, and a semiquantitative classification by the index was coincident with angiographic severity in 38 of 43 (88.4%) patients undergoing MR, and in 28 of 30 (93.3%) patients undergoing AR. Thus, cMRI is a clinically useful noninvasive method in the identification and semiquantitative assessment of regurgitation severity.
No takes yet. Share an insight, caveat, or question.
Nishimura et al. (1990) conducted an observational in Valvular regurgitation (n=104). Cine-MR imaging (cMRI) vs. Cineangiography was evaluated on Accuracy of diagnosis of valvular regurgitation (sensitivity and specificity). Cine-MR imaging demonstrated high diagnostic accuracy for valvular regurgitation compared to cineangiography, with sensitivities of 93.5% for MR, 100% for AR, and 85.7% for TR.
Synapse has enriched 10 related papers. Consider them for comparative context: