Why the study?
Does intracardiac echocardiography (ICE) guided left ventricular lead placement using vector velocity imaging (VVI) improve CRT response rates in heart failure patients undergoing CRT implantation?
Does intracardiac echocardiography (ICE) guided left ventricular lead placement using vector velocity imaging (VVI) improve CRT response rates in heart failure patients undergoing CRT implantation?
ICE-guided LV lead placement using VVI during CRT implantation is safe and significantly increases the rate of CRT responders at 6 months compared to conventional implantation.
May increase CRT responders with ICE/VVI; leaves open need for randomized confirmation before practice change.
INTRODUCTION: Intraoperative modality for "real-time" left ventricular (LV) dyssynchrony quantification and optimal resynchronization is not established. This study determined the feasibility, safety, and efficacy of intracardiac echocardiography (ICE), coupled with vector velocity imaging (VVI), to evaluate LV dyssynchrony and to guide LV lead placement at the time of cardiac resynchronization therapy (CRT) implant. METHODS: One hundred and four consecutive heart failure patients undergoing ICE-guided (Group 1, N = 50) or conventional (Group 2, N = 54) CRT implant were included in the study. For Group 1 patients, LV dyssynchrony and resynchronization were evaluated by VVI including visual algorithms and the maximum differences in time-to-peak (MD-TTP) radial strain. Based on the findings, the final LV lead site was determined and optimal resynchronization was achieved. CRT responders were defined using standard criteria 6 months after implantation. RESULTS: Both groups underwent CRT implant with no complications. In Group 1, intraprocedural optimal resynchronization by VVI including visual algorithms and MD-TTP was a predictor discriminating CRT response with a sensitivity of 95% and specificity of 89%. Use of ICE/VVI increased number of and predicted CRT responders (82% in Group 1 vs 63% in Group 2; OR = 2.68, 95% CI 1.08-6.65, P = 0.03). CONCLUSION: ICE can be safely performed during CRT implantation. "Real-time" VVI appears to be helpful in determining the final LV lead position and pacing mode that allow better intraprocedural resynchronization. VVI-optimized acute resynchronization predicts CRT response and this approach is associated with higher number of CRT responders.
No takes yet. Share an insight, caveat, or question.
Bai et al. (2011) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: