Why the study?
Does the frequency of intraprocedural PVCs at the beginning of the procedure affect the success rate of catheter ablation in patients with frequent idiopathic PVCs?
Does the frequency of intraprocedural PVCs at the beginning of the procedure affect the success rate of catheter ablation in patients with frequent idiopathic PVCs?
The paucity of PVCs at the beginning of an ablation procedure is a strong independent predictor of procedural failure in patients with frequent idiopathic PVCs.
Paucity of intraprocedural PVCs may predict ablation failure; hypothesis-generating for procedural planning in idiopathic PVCs pending prospective validation.
BACKGROUND: Frequent premature ventricular complexes (PVCs) can be eliminated with an ablation procedure. Ablation success rates have been reported to be in the 80% range. Reasons for failure of ablation have not been described in detail. The purpose of this study was to determine whether the paucity of PVCs at the beginning of the ablation procedure affects the outcome. METHODS: Catheter ablation was attempted in a consecutive series of 194 patients (age: 50 ± 14 years, 91 male, ejection fraction: 56.4 ± 8.4%) with frequent idiopathic PVCs. Based on receiver operator characteristics (ROC) analysis, patients were divided into 2 groups: Patients with frequent PVCs (≥32 PVCs within the first 30 minutes of the procedure: n = 135 [70%]); and patients with infrequent PVCs (<32 PVCs within the first 30 minutes of the procedure: n = 59 [30%]). Procedural outcomes were compared at 3 months postablation. A successful ablation was defined as a ≥80% reduction in the PVC burden compared to baseline. RESULTS: A successful procedure was performed in 148 patients (76%) resulting in a decrease in the PVC burden from 19.1 ± 13.6% to 0.38 ± 0.98%(P < 0.0001). Patients with frequent intraprocedural PVCs had a higher success rate than patients with infrequent intraprocedural PVCs (85% vs. 56%, P = 0.0001). Administration of sedation was no different in the 2 groups. The paucity of PVCs was independent of the site of origin in predicting procedural failure (OR: 6.9, 95% CI: 3.0-16.2 P = 0.0001). CONCLUSION: Paucity of PVCs at the beginning of an ablation procedure is associated with a lower ablation success rate independent of the site of origin.
No takes yet. Share an insight, caveat, or question.
Başer et al. (2014) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: