Why the study?
The study was conducted to compare echocardiographic and invasive mean gradients obtained concomitantly in degenerated bioprosthetic surgical aortic valves.
Is there discordance between echocardiographic and invasive mean gradients in patients with degenerated surgical aortic valve prostheses?
Is there discordance between echocardiographic and invasive mean gradients in patients with degenerated surgical aortic valve prostheses?
Echocardiographic and invasive mean gradients are often discordant in degenerated surgical aortic valves, particularly in regurgitant or mixed disease, suggesting invasive hemodynamics may be needed when echocardiography conflicts with clinical findings.
Answers are grounded in this paper and cite their sources.
May warrant invasive confirmation when echo gradients conflict with clinical findings in degenerated SAVR; leaves open prospective validation in stenosis-dominant cohorts.
ObjectivesTo compare echocardiographic and invasive mean gradients obtained concomitantly in degenerated bioprosthetic surgical aortic valves (SAVRs).MethodsIn a multicenter study, we compared concomitant echocardiographic and invasive mean gradients of SAVR, obtained before valve-in-valve transcatheter aortic valve replacement in all patients, patients with primary stenosis (AS), primary aortic regurgitation (AR), and mixed aortic valve disease (MAVD), and in small versus large valves (≤ or >23 mm). Dimensionless index (DI) was calculated in all groups.ResultsIn total, 74 patients were included and data presented as median (interquartile range). Echocardiography-catheterization mean gradient discordance was observed in all patients (invasive = 22 mm Hg [11-34] vs echocardiographic = 32 mm Hg [21-42], P = .013), small valves (invasive = 15 mm Hg [8-34] vs echocardiographic = 28 mm Hg [21-41], P = .013), and large valves (invasive = 20 mm Hg [8.5-27.13] vs echocardiographic = 32 mm Hg [25.5 ̶ 41.5], P < .0001), with a bias of 8 ± 15 mm Hg and wide limits of agreement (–22 to 39 mm Hg) on Bland–Altman plots, indicating these modalities may not be interchangeable. Discordance occurred in AR (invasive = 3 mm Hg [1-6] vs echocardiographic = 12 mm Hg [7-22], P = .017) and in MAVD (invasive = 19 mm Hg [12-29] vs echocardiographic = 31 mm Hg [23-39], P < .0001) but not in AS (invasive = 35 mm Hg [24-45] vs echocardiographic = 41 mm Hg [30-50], P = .45). A lower DI (0.21 [0.14-0.25]) occurred in AS compared with MAVD (0.31 [0.19-0.39]) and AR (0.55 [0.51-0.69]), P < .0001.ConclusionsDiscordance between echocardiography and invasive mean gradients exists in degenerated SAVR, regardless of valve size, but depends on mechanism of failure and DI helps stratify these patients. With a discrepancy between echocardiographic mean gradients AND the patient's symptoms OR the valve leaflet structure and/or mobility on imaging, especially before redo-SAVR or valve-in-valve transcatheter aortic valve replacement, invasive gradients may adjudicate the true valvular hemodynamics.
No takes yet. Share an insight, caveat, or question.
Kadri et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: