Key result
Pulse wave transit time correlates strongly and inversely with sPAP in acute pulmonary hypertension.
Why the study?
Surrogates like pulse wave transit time have been proposed for non-invasive pulmonary artery pressure assessment, but invasive validation of which pressure type it best reflects was needed.
Does pulse wave transit time correlate with pulmonary artery pressure in a porcine model of pulmonary hypertension?
Does pulse wave transit time correlate with pulmonary artery pressure in a porcine model of pulmonary hypertension?
Effect estimate: r = 0.809
p-value: p=≤0.001
Pulse wave transit time shows a strong negative linear correlation with pulmonary artery pressure, particularly systolic PAP, establishing a physiological basis for future non-invasive PAP estimation methods.
Supports PWTT-PAP correlation in acute porcine models; leaves open non-invasive human validation.
For the non-invasive assessment of pulmonary artery pressure (PAP), surrogates like pulse wave transit time (PWTT) have been proposed. The aim of this study was to invasively validate for which kind of PAP (systolic, mean, or diastolic) PWTT is the best surrogate parameter. To assess both PWTT and PAP in six healthy pigs, two pulmonary artery Mikro-Tip™ catheters were inserted into the pulmonary vasculature at a fixed distance: one in the pulmonary artery trunk, and a second one in a distal segment of the pulmonary artery. PAP was raised using the thromboxane A2 analogue U46619 (TXA) and by hypoxic vasoconstriction. There was a negative linear correlation between PWTT and systolic PAP (r = 0.742), mean PAP (r = 0.712) and diastolic PAP (r = 0.609) under TXA. During hypoxic vasoconstriction, the correlation coefficients for systolic, mean, and diastolic PAP were consistently higher than for TXA-induced pulmonary hypertension (r = 0.809, 0.778 and 0.734, respectively). Estimation of sPAP, mPAP, and dPAP using PWTT is feasible, nevertheless slightly better correlation coefficients were detected for sPAP compared to dPAP. In this study we establish the physiological basis for future methods to obtain PAP by non-invasively measured PWTT.
No takes yet. Share an insight, caveat, or question.
Müller‐Graf et al. (2021) studied Pulmonary hypertension (n=6). Thromboxane A2 analogue U46619 and hypoxic vasoconstriction vs. Baseline (resting conditions) was evaluated on Correlation between pulse wave transit time and systolic pulmonary artery pressure during hypoxia (r = 0.809, p=≤0.001). Pulse wave transit time demonstrated a strong negative linear correlation with systolic pulmonary artery pressure during hypoxia-induced (r = 0.809) and thromboxane A2-induced (r = 0.742) acute pulmonary hypertension in a porcine model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: