Key result
The 3D cine Dixon MRI technique quantified epicardial fat volume at 145 ml compared to 165 ml with single-phase Dixon (p<0.01), demonstrating lower intra- and inter-observer variability.
Why the study?
Epicardial fat is linked to cardiovascular diseases, but the merits of a new high-resolution cine 3D Dixon technique compared to single-phase 3D Dixon needed investigation.
Does 3D cine Dixon MRI improve the reproducibility of epicardial fat quantification compared to single-phase 3D Dixon MRI in patients with known or suspected heart disease?
Cross-Sectional (n=15)
Single-blind
No
Does 3D cine Dixon MRI improve the reproducibility of epicardial fat quantification compared to single-phase 3D Dixon MRI in patients with known or suspected heart disease?
Cine 3D Dixon MRI provides more reproducible epicardial fat quantification than standard single-phase Dixon MRI by utilizing time-resolved information to better delineate fat borders.
May support cine Dixon for reproducible epicardial fat research measures; leaves open clinical impact in heart disease.
Background: There is an increased interest in quantifying and characterizing epicardial fat which has been linked to various cardiovascular diseases such as coronary artery disease and atrial fibrillation. Recently, three-dimensional single-phase Dixon techniques have been used to depict the heart and to quantify the surrounding fat. The purpose of this study was to investigate the merits of a new high-resolution cine 3D Dixon technique for quantification of epicardial adipose tissue and compare it to single-phase 3D Dixon in patients with cardiovascular disease. Methods: Fifteen patients referred for clinical CMR examination of known or suspected heart disease were scanned on a 1.5T scanner using single-phase Dixon and cine Dixon. Epicardial fat was segmented by three readers and intra- and inter-observer variability was calculated per slice. Cine Dixon segmentation was performed in the same cardiac phase as single-phase Dixon. Subjective image quality assessment of water and fat images were performed by three readers using a 4-point Likert scale (1=severe; 2=significant; 3=mild; 4=no blurring of cardiac structures). Results: Intra-observer variability was excellent for cine Dixon images (ICC=0.96), and higher than single-phase Dixon (ICC=0.92). Inter-observer variability was good for cine Dixon (ICC=0.76) and moderate for single-phase Dixon (ICC=0.63). The intra-observer measurement error (mean ± standard deviation) per slice for cine was -0.02±0.51 ml (-0.08±0.4%), and for single-phase 0.39±0.72 ml (0.18±0.41%). Inter-observer measurement error for cine was 0.46±0.98 ml (0.11±0.46%) and for single-phase 0.42±1.53 ml (0.17±0.47%). Visual scoring of the water image yielded median of 2 (interquartile range = [Q3-Q1] 2-2) for cine and median of 3 (interquartile range = 3-2) for single-phase ( P < 0.05) while no significant difference was found for the fat images, both techniques yielding a median of 3 and interquartile range of 3-2. Conclusion: Cine Dixon can be used to quantify epicardial fat with lower intra- and inter-observer variability compared to standard single-phase Dixon. The time-resolved information provided by the cine acquisition appears to support the delineation of the epicardial adipose tissue depot.
No takes yet. Share an insight, caveat, or question.
Henningsson et al. (2020) conducted a cross-sectional in Known or suspected heart disease (n=15). 3D cine Dixon MRI vs. Single-phase 3D Dixon MRI was evaluated on Epicardial fat volume (p=<0.01). The 3D cine Dixon MRI technique quantified epicardial fat volume at 145 ml compared to 165 ml with single-phase Dixon (p<0.01), demonstrating lower intra- and inter-observer variability.