Key result
Brain MRI in patients with cardiovascular implantable electronic devices did not significantly increase 5-year mortality compared to brain CT (HR 0.814; 95% CI 0.593-1.117; P=0.2).
Why the study?
Does brain MRI increase mortality in patients with non-MRI-conditional CIEDs compared to controls?
Cohort
Does brain MRI increase mortality in patients with non-MRI-conditional CIEDs compared to controls?
Brain MRI in patients with non-MRI-conditional CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with appropriate protocols.
Supports brain MRI in CIED patients versus CT; leaves open need for randomized confirmation of safety.
Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
No takes yet. Share an insight, caveat, or question.
Padmanabhan et al. (2018) conducted a cohort in Cardiovascular implantable electronic devices (CIEDs). Brain MRI vs. Brain CT (with or without CIED) and Brain MRI without CIED was evaluated on All-cause mortality at 5 years (HR 0.814, 95% CI 0.593-1.117, p=0.2). Brain MRI in patients with cardiovascular implantable electronic devices did not significantly increase 5-year mortality compared to brain CT (HR 0.814; 95% CI 0.593-1.117; P=0.2).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: