Key result
A novel cuffless blood pressure estimation technique using ECG and BCG measured on a weighing scale showed reliable correlation with reference systolic blood pressure measurements.
Why the study?
Does a novel technique using ECG and BCG on a weighing scale accurately estimate systolic blood pressure compared to a reference system?
Does a novel technique using ECG and BCG on a weighing scale accurately estimate systolic blood pressure compared to a reference system?
A novel technique using ECG and BCG measured on a weighing scale provides reliable estimates of systolic blood pressure compared to a reference system, enabling potential home healthcare monitoring.
Answers are grounded in this paper and cite their sources.
May enable convenient home BP monitoring; hypothesis-generating pending larger validation studies.
In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured using three different methods: on the chest using Ag/AgCl electrodes, on the hands using dry electrodes and on the feet also using dry electrodes. For a BP correlated parameter, a time interval parameter, which was defined as the time difference between the ECG R-peak and BCG J-peak, was employed for evaluating and estimating beat-to-beat BP. Under a BP varying experiment with a Valsalva manoeuvre, the R-J intervals were extracted at every beat cycle and a systolic blood pressure (SBP) estimation equation was established using linear regression analysis for each subject. In the case of feet delivered ECG (F-ECG), an ensemble average technique synchronized at the BCG J-peak point was applied to extract the ECG signal from the feet. The performance of the proposed method was evaluated using Finapres, a non-invasive blood pressure measurement system, as a reference BP signal, and a scatter plot was used to find the regression line between the reference values and estimated BPs. A moving-window averaging technique was applied to remove the high-frequency noise in the R-J intervals and was applied to enhance the accuracy of the SBP estimation. For all individuals, the estimated SBP was similar to the measured SBP with a reliable correlation, which makes the proposed method suitable for use in a home healthcare system to monitor blood pressure on a weighing scale at the same time as measuring weight.
No takes yet. Share an insight, caveat, or question.
Shin et al. (2009) studied Blood pressure monitoring. Cuffless blood pressure estimation using ECG and BCG on a weighing scale vs. Finapres non-invasive blood pressure measurement system was evaluated on Systolic blood pressure estimation accuracy. A novel cuffless blood pressure estimation technique using ECG and BCG measured on a weighing scale showed reliable correlation with reference systolic blood pressure measurements.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: